23
ECO 60 / 70 / 90 / 100
This will not only avoid poor combustion, but will also prevent flue gases
being sucked from the appliance into the room.
Should creating an extra ventilation opening prove insufficient, it is then
necessary to fit a flue gas fan.
•
Combustion air directly from outside
:
The appliance now has a completely closed combustion syst
em
, which
allows it to operate independently of the surrounding air in the room where
the appliance is located.
3.4.
FITTING THE STOVE
3.4.1.
Connecting the smoke outlet
ECO 60:
The appliance can make use of either a
top or rear
connection Ø150 mm
(
Ø150 mm external) for the flue (chimney).
The appliance is supplied with the flue gas exhaust flue connection and cover
plate that was stated with the order.
Assembling of the
smoke outlet
ECO 60
top connection
:
-
Install the cast-iron flue gas exhaust flue connection ring to the top of the
appliance.
Attention !
Ensure that the sealing cord
fits properly all round.
Содержание ECO 60
Страница 2: ......
Страница 3: ...3 ECO 60 70 90 100 ECO 60 Floor plate is optional ECO 90 ECO 70 ECO 100...
Страница 4: ...4 ECO 60 70 90 100...
Страница 10: ...10 ECO 60 70 90 100...
Страница 69: ...69 ECO 60 70 90 100 Remove the left side panel Take care that the rear panels do not fall forwards...
Страница 70: ...70 ECO 60 70 90 100 Remove the right side panel Take care that the rear panels do not fall forwards...
Страница 72: ...72 ECO 60 70 90 100 12 DIMENSIONS 12 1 ECO 60...
Страница 73: ...73 ECO 60 70 90 100 12 2 ECO 70...
Страница 74: ...74 ECO 60 70 90 100 12 3 ECO 90...
Страница 75: ...75 ECO 60 70 90 100 12 4 ECO 100 SOAPSTONE...
Страница 82: ...82 ECO 60 70 90 100...
Страница 83: ......