21
ECO 60 / 70 / 90 / 100
Important:
• Chimneys must be free-standing, i.e. they must not rest on the appliance
itself.
• Any pipe connections that are not insulated must also be fully insulated.
• Flammable material must be kept clear (outside the casing/insulation zone)
of all through-feeds in the floor or wall (remember the roof decking).
• The chimney opening must be at least 5 metres above the top of the door
opening of your appliance.
• The chimney must protrude at least 40 cm above the apex of a sloping roof
and at least 1 metre above a flat roof. In short, the chimney must always end
in an area with a negative air pressure. Contact your local chimney sweep for
the exact dimensions of the chimney opening.
Between the stove and chimney, use thick-walled smoke piping (Steel,
≥
2 mm).
See Chapter 2.2.
The first pipe connected to the appliance must have a diameter of 150 mm (
int.
)
at both ends. This will prevent any condensation from the chimney running over
the external end of the pipe. Connect the pipes to the existing chimney (ceiling)
using a sliding sleeve (niche pipe). Check all connections for air-tightness.
If there is too much draught running through your chimney (e.g. if the chimney is
long and straight in a tall building), it may be possible to insert a chimney valve
in the pipe near the appliance. Before doing this, be sure to obtain sound advice
from a specialist.
Do not make any horizontal connections. Deposits and soot will accumulate here
(unless it is a short horizontal connection directly behind the stove).
Avoid bends at all costs. The maximum deviation from the perpendicular is 45°.
The chimney calculation, as in Germany, is made according to DIN 4705 parts
1 and 2.
Содержание ECO 60
Страница 2: ......
Страница 3: ...3 ECO 60 70 90 100 ECO 60 Floor plate is optional ECO 90 ECO 70 ECO 100...
Страница 4: ...4 ECO 60 70 90 100...
Страница 10: ...10 ECO 60 70 90 100...
Страница 69: ...69 ECO 60 70 90 100 Remove the left side panel Take care that the rear panels do not fall forwards...
Страница 70: ...70 ECO 60 70 90 100 Remove the right side panel Take care that the rear panels do not fall forwards...
Страница 72: ...72 ECO 60 70 90 100 12 DIMENSIONS 12 1 ECO 60...
Страница 73: ...73 ECO 60 70 90 100 12 2 ECO 70...
Страница 74: ...74 ECO 60 70 90 100 12 3 ECO 90...
Страница 75: ...75 ECO 60 70 90 100 12 4 ECO 100 SOAPSTONE...
Страница 82: ...82 ECO 60 70 90 100...
Страница 83: ......