7.4 Logging out
Entry
Display
Description
or
The following prerequisites apply logging out:
-
The hand-held transmitter is paired with the system.
-
The hand-held transmitter is logged in.
-
The hand-held transmitter is located in the receiving field.
or
The system is built into the truck:
Press “Truck” pushbutton for longer than 0.5 seconds.
Hand-held transmitter logged out: The green LED and red
LED under the truck symbol are out.
The system is built into the trailer:
Press “Trailer” pushbutton for longer than 0.5 seconds.
Hand-held transmitter logged out: The green LED and red
LED under the trailer symbol are out.
The control voltage of the Cargolift is also switched off
when the hand-held transmitter is logged out.
The stop pushbutton has the highest priority, ensuring safe
stopping of the Cargolift.
By pressing the Stop pushbutton, the system executes the
following:
-
Hand-held transmitter is logging out.
-
The control voltage of the Cargolift on which the system
with the logged in hand-held transmitter is located is
switched off.
-
The control voltage of a Cargolift that is dynamically
paired with this Cargolift is switched off.
-
The hand-held transmitter is switched off.
Automatic
If no pushbutton has been pressed on the hand-held transmitter
for more than 1 minute, it goes into stand-by mode and the LED
display switches off. The login remains, and the Cargolift is not
switched off.
If a pushbutton has not been pressed on the hand-held
transmitter for more than 8 minutes, it logs itself off the system
automatically and the Cargolift is switched off.
fa
h >0.5s
1x
h >0.5s
1x