INSTRUCTIONS FOR INSTALLING WALL􀀁MOUNT SPEED  CONTROL

105F &105FR

Safety Warning! Please Read Carefully 

 

Unit should be installed by a qualified electrician in accordance with the national electrical code and other 
local codes which may apply. This control must be grounded when installed. Failure  
to follow these instructions may result in electrical shock or a fire hazard. To reduce the risk of fire or 
electric shock, this control is lo be used only with fans marked as suitable for use with said slate speed 
controls. This control is suitable for mounting in a metal or polymeric field enclosure. These controls must 
not be used at ratings exceeding those clearly marked on the device.  
We are not responsible for any expense inconvenience or consequential damage caused by  
items of our manufacture or sale.  

 

Application

 

a) Motor Type - Shaded Pole. P.S.C., and Universal.  
b) Required Load - Fans. Blowers and speed dependent loads.

Wiring

Warning! Power must be turned off before wiring.  
Connect control in series with motor and line voltage: never connect control across line.  
Ground (earth) - Be sure to ground control using the green wire. 

Some models do not require grounding. 1herefore a ground wire is not provided.

Mounting

a) Use 2” deep standard electrical box. 
b) Secure control with outer bracket tabs

Minimum Speed Adjustment

Important: If this option is not supplied, disregard step 4 and continue lo step 5.  
This control was designed to operate on motors used in diverse applications. A minimum speed adjustment 
is provided to allow independent control of the minimum speed setting. Minimum speed adjustment 
ensures motor runs with sufficient torque to prevent staling.

a)  Motor must be in actual operating conditions lo achieve proper speed adjustment. Motor  
  will not slow down unless proper load is applied. 

b)  Turn main control knob lo lowest speed position. 

c)  Locate and adjust minimum speed setting on front plate with screw driver 
  (rotate clockwise lo decrease minimum speed; counter-clockwise to increase minimum speed).  

 

Special Note: For 2.5 and 3.0 Amp models, adjustment of minimum speed is reversed.  
Rotate clockwise to increase minimum speed: counter-clockwise lo decrease minimum speed.  
On some models minimum speed adjustment hole is localed on side of control. 

d)  Motor will now operate from this preset minimum speed to full speed.

Final Mounting

a)  Install front dial plate (remove protective plastic on face of dial plate).
b)  Turn main control until switch snaps off. (Switch models only).
c)  Push on knob so that pointer is in off position.

Connection Diagram for 2 Wire Controls 105F

AC Line

Controled 

Load

L2

L1

Triac

Switch

Green

Ground/Earth*

Connection Diagram for Model 105FR Control

AC Line

Controled 

Load

L2

L1

Green

Ground/Earth*

Blue

Motor Control

Black

Red

*Ground wire is not counted when designating 2, 3 or 4 wire controls.

Banvil2000 Limited Warranty

 

Banvil2000 warrants to the original consumer purchaser that this product is free of defects in materials and 
workmanship for one year from purchase date. Banvil w􀀁I correct such defects by repair or replacement at its
option, if the product is returned prepaid, with proof of purchase date to Banvil2000, (division of 3383768 
Canada ltd., 775 Main Street, East Milton, ON LST 3Z3). This Warranty does not cover labour for removal or 
re-installationof the prod uc t and is void on any product improperly installed. overload, abused or altered 
in any manner. Banvil limits the duration of any implied warranty of one year which excludes incidental or 
consequential damages for breach of any warranty on this product.

Banvil2000 | 905.878.1080 | www.banvil2000.com