Troubleshooting
13.7.1 Industrial Ethernet Error Codes
The VE Series camera provides error codes when coil bit commands fail to execute successfully.
If such an error occurs, the
Execution
Error
flag
is set in the Output Bits/Status Register. When this bit is set, read the Error Code register
to know the reason for the failure.
Error Code
Description
Recommended
Solution
520
The coil
action
resulted in a failure.
Clear all coil bits. Verify that the corresponding acknowledgement bits are
reset to zero. The error code will clear when the next valid command is
issued.
524
Multiple
coils were asserted
simultaneously.
Clear all coil bits. Verify that the corresponding acknowledgement bits are
reset to zero. The error code will clear when the next valid command is
issued.
80400
The sensor must be in the Ready state
to perform a product change.
Clear the Product Change bit. Verify that the Product Change
acknowledgement bit has been reset to zero. Wait
until
the sensor is Ready.
Re-assert the Product Change bit.
80401
Attempt
to product change to a
unknown or invalid
inspection.
Clear the Product Change bit. Verify that the Product Change
acknowledgement bit has been reset to zero. Set the
inspection
slot to a
valid value. Re-assert the Product Change bit.
13.7.2 PROFINET
Discovering Sensors
The Siemens TIA Portal (v13)
software
discovery and
configuration
protocols are used to discover sensors on a network.
1. Start the Siemens TIA Portal (v13)
software.
2. Click Open an
existing
project.
3. Select a project and open it.
4. Click Devices & networks
after
the project has been uploaded.
5. Click
Configure
networks.
VE Series Smart Camera
210
www.bannerengineering.com - Tel: 763.544.3164