Inspection
Pass/Fail
Select the Contribute to
Inspection
Pass/Fail check box (default) if the tool will
influence
the Pass/Fail status of the
inspection.
Figure 223.
Inspection
Pass/Fail
The Pass/Fail
contribution
influences
the following:
• Discrete output Pass
• Discrete output Fail
• Pass/Fail results counter
• Pass (Green) and Fail (red) LEDs on the Sensor
Select this checkbox if the overall Pass/Fail status of the
inspection
is dependent on the current tool.
8.9.2 Match Tool: Test Parameters
Use the Test parameters to
configure
the pass/fail
conditions
for the tool.
Select the parameter checkbox to enable it. Where applicable, the
vertical
green bar shows the current parameter
information
and the
light gray backgrounds show the range over which a value has varied over
time.
Where applicable, use the sliders or enter the minimum and maximum for the selected test parameters.
Figure 224. Match Tool—Test Parameters
Count
The number of matching
patterns.
Individual Matches
Specific
Match—Select First Match or
Specific
Match.
Centroid X—The
location
of the point of the center of
mass of the selected match on the x axis.
Centroid Y—The
location
of the point of the center of
mass of the selected match on the y axis.
Angle—The rotated angle of the matching object.
Offset
Point X
The x-dimension
offset
between the current match and
the reference point.
Available when Adjust Downstream Tool ROIs is enabled.
Offset
Point Y
The y-dimension
offset
between the current match and
the reference point.
Available when Adjust Downstream Tool ROIs is enabled.
Offset
Angle
The angular
difference
between the current angle and the
angle from the reference point.
Available when Adjust Downstream Tool ROIs is enabled.
8.9.3 Match Tool: Results
Tools & Results and All Results list
information
from the current and previous
inspections.
A red box around a tool indicates that the tool failed. Status provides
information
about the
specific
failure.
All Results displays the Result, Time, Pass Count, and Fail Count
information
at a glance. Expand the
inspection
tool to see
specific
results for that tool.
Count
The number of matching
patterns.
Percentage Range
The percentage by which the found objects match the reference object. Expand Percentage Range to view the centroid (center
point), angle, and percent match for the objects found within the ROI.
VE Series Smart Camera