TCNM-ACM-OM110 Installation Manual 

 

1 – Laser beam output window 
2 – Power cable 

Содержание TCNM-ACM-OM110

Страница 1: ...Sep 2013 p n 174698 Rev A TCNM ACM OM110 Installation Manual 1 Laser beam output window 2 Power cable ...

Страница 2: ... on the reading surface and codes with printing defects The electronic and electromechanical components controlling the mirror movement are contained inside the rugged metal casing which guarantees protection class IP65 when the TCNM ACM OM110 is mounted correctly onto the scanner The TCNM ACM OM110 is directly powered from the scanner through a connector that is accessible after removing the scan...

Страница 3: ...brasive substances because they cause irreparable damage to the transparency of the glass Step 2 Remove the scanning window from the scanner Step 3 Bring the TCNM ACM OM110 close to the scanner and insert the cable into the scanner s power connector Make sure the cable doesn t remain in the path of the mirror movement Step 4 Check that the seal is correctly positioned align the TCNM ACM OM110 onto...

Страница 4: ...X series scanner with the TCNM ACM OM110 is shifted by 10 mm toward the scanner because of the internal optical path between the scanner and the TCNM ACM OM110 output window The reading performance also decreases in typical conditions by about 10 due to the optical signal passing through the output window of the TCNM ACM OM110 and the reflection on the mirror surface The combination of these effec...

Страница 5: ... mounted to a TCNM AD EX scanner and is configurable exclusively through the GeniusPlus utility program When entering the SMART TEACH interface on the TCNM AD EX the Oscillating Mirror remains in the default fixed position 15 in order to make barcode reading easier while performing the SMART TEACH functions The following software configuration parameters are available through GeniusPlus and descri...

Страница 6: ...ng zone according to the parameters set Values are Active Open Active Closed Second Zone Oscillating Mode Defines the oscillating mode of the scanner mirror to be used in the second reading zone Values are Fixed The oscillating mirror deflects the scan line at a fixed angle of deflection 15 Continuous The scan line is deflected according to the Second Zone Amplitude and Second Zone Frequency setti...

Страница 7: ...ure 0 to 45 C 32 to 113 F Storage Temperature 20 to 70 C 4 to 158 F Humidity Max 90 non condensing Vibration Resistance EN 60068 2 6 14 mm 2 10 Hz 1 5 mm 13 55 Hz 2 g 70 200 Hz 2 hours on each axis Bump Resistance EN 60068 2 29 30 g 6 ms 5000 shocks on each axis Shock Resistance EN 60068 2 27 30 g 11 ms 3 shocks on each axis Protection Class EN 60529 IP65 when correctly mounted to the scanner Phys...