June 23, 2023
T30RW R-GAGE Washdown Radar Sensor Instruction Manual
25
Reset the Sensor to Factory Defaults
Reset the sensor to factory default settings using one of two methods.
NOTE:
If a factory reset is performed through the
Banner Radar Configuration
Software, the remote input
wire becomes disabled (factory default setting). If the sensor is returned to factory defaults by using the
remote input wire, the input wire remains enabled and the rest of the settings are restored to factory
defaults.
To reset using the
Banner Radar Configuration
software, go to
Sensor
›
Factory Reset. The sensor indicators flash once, the
sensor is reset back to the factory default settings, and a confirmation message displays.
To reset using the remote input, eight-pulse the remote input to apply the factory defaults.
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T30RW Factory Default Settings
General Tab Default Settings
Setting
Factory Default
Response Speed
Slow
Signal Strength Threshold
3.0
Target Mode
Nearest Target
Measurement Hold
Disabled
Discrete Output & Remote Input
PNP
Remote Input Wire
Disabled
Push Buttons
Enabled
Analog Tab Default Settings
Setting
Factory Default
Range
4 mA to 20 mA
(0 V to 10 V)
4mA/0V Point
0.3 m (1 ft)
20mA/10V Point
15.0 m (49.2 ft)
Loss of Signal
3.5 mA (0 V)
Averaging
1× (no averaging)
Discrete 1 Tab Default Settings
Setting
Factory Default
Output Mode
Switch Point
Setpoint 1
15.0 m (49.2 ft)
Hysteresis
0.05 m (2 in)
NO/NC
Normally Open
Continued on page 26
© Banner Engineering Corp.
Содержание T30RW
Страница 3: ...3 Banner Engineering Corp Software Copyright Notice 41 Banner Engineering Corp Limited Warranty 41...
Страница 4: ...Blank page 4...
Страница 8: ...Blank page 8...
Страница 18: ...Blank page 18...
Страница 28: ...Blank page 28...
Страница 34: ...Blank page 34...
Страница 36: ...Blank page 36...
Страница 40: ...Blank page 40...
Страница 43: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...