June 23, 2023
T30RW R-GAGE Washdown Radar Sensor Instruction Manual
17
Output Settings
Available when Output Mode is set to
Switch Point
or
Window
.
NO/NC
: Select
Normally Open
or
Normally Closed
from the list.
On Delay
: Set an on delay in milliseconds. The maximum time is 60,000 ms.
Off Delay
: Set an off delay in milliseconds. The maximum time is 60,000 ms.
Response Time
Calculates the total response time, taking into account the general response speed and on or off delays.
Discrete
Response Speed
Discrete Output ON Spec (ms)
Discrete Output OFF Spec (ms)
Fast
6
6
Medium
50
100
Slow
200
500
Pulse Pro/PFM Settings
Available when Output Mode is set to
Pulse Pro/PFM
.
The
T30RW
can generate pulses whose frequency are proportional to the sensor's measured distance, thereby providing
a method for representing an analog signal with only a discrete counter. The sensing range of the sensor is scaled from
100 Hz to 600 Hz. 100 Hz equals the near range limit of the sensor, and 600 Hz equals the far sensing range limit. An
output of 50 Hz or 650 Hz (user defined in the software) represents a loss of signal condition where there is no target or
the target is out of range. This output can be tied directly to a number of Banner lights for visual feedback without the
need for a controller.
100 Hz:
Define the near sensing range limit of the Pulse Pro range.
600 Hz
: Define the far sensing range limit of the Pulse Pro range.
Loss–of–Signal
: Sets the value used by the sensor during a loss of signal. When a signal is restored, measurement
resumes.
Hold last value—The Discrete 2 Output holds the last value indefinitely during a loss of signal.
50 Hz—The Discrete 2 Output switches to this value 2 seconds after a loss of signal.
650 Hz—The Discrete 2 Output switches to this value 2 seconds after a loss of signal.
Live Sensor Data Controls
After connecting to the sensor, data sampling begins automatically (but not recording).
To stop data sampling, click
Stop.
To restart data sampling, click
Play
. This only samples data from the sensor and displays it on the plot; it does not record
the data to a log file.
To record data to a log file, click
Record
. The log file selection prompt displays. Save the log file as desired. The log file
format is .csv.
If communication to the sensor is lost, click
Refresh Device Connection to reconnect.
© Banner Engineering Corp.
Содержание T30RW
Страница 3: ...3 Banner Engineering Corp Software Copyright Notice 41 Banner Engineering Corp Limited Warranty 41...
Страница 4: ...Blank page 4...
Страница 8: ...Blank page 8...
Страница 18: ...Blank page 18...
Страница 28: ...Blank page 28...
Страница 34: ...Blank page 34...
Страница 36: ...Blank page 36...
Страница 40: ...Blank page 40...
Страница 43: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...