![Banner SX5 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/banner/sx5/sx5_instruction-manual_3759267083.webp)
Configuration
Accepted
Configuration Not
Accepted
Name
Description
Safety Zone Signal
The device is correctly functioning. The device has detected an object
in the Safety Zone.
Reference Point Signal
Reference points have moved. The display sector in the direction of
the moved point is shown in blue.
9.4 Diagnostic Notes, Warnings, and Errors
Icon
Fault Code
Device Status
OSSD Status
Description
DLDNF
Normal
Off
Downloading the new firmware.
DLDNC
Normal
Off
Downloading the new configuration.
CLEANW2
Normal
On
Clean the window to avoid a lockout condition.
ITLOCK1
Normal
Off
Interlock; waiting for a restart signal to turn the OSSDs back on.
INTF6
Normal
On
Non-safety related internal test failure.
Reset the system using the reset function or cycle the power to the
device.
If the failure persists, contact the factory for support.
EXTTEMP
Normal
On
The device is operating in an environment that exceeds the specified
operating temperature range. Restore the correct ambient temperature
conditions.
BOOTF
Normal
Off
Invalid boot. Re-boot the system until the normal condition is restored.
If warning persists, contact the factory for support.
SX5 Safety Laser Scanner
www.bannerengineering.com - Tel: +1.763.544.3164
83