Safety Data
Type 3 (EN 61496-1)
SIL 2 (IEC 61508)
Category 3 (EN ISO 13849-1)
SILCL 2 (EN 62061)
PL d (EN ISO 13849-1)
PFHd (mean probability of a dangerous failure per hour): 6.38 × 10
-8
SFF: 97.58%
MTTFd: 61 Years
TM (mission time): 20 years (EN ISO 13849-1)
HFT (Hardware Fault Tolerance): 1
State of safety: OSSD in OFF State (open circuit
→
I OSSD = 0)
Response time to malfunction: ≤ Response Time
Operating Conditions
0 °C to +50 °C (+32 °F to +122 °F)
7
95% maximum relative humidity (non-condensing) (According to IEC
61496-1 5.4.2; IEC 61496-3 5.4.2; 4.3.1; 5.4.4.3)
Storage Conditions
–20 °C to +70 °C (–4 °F to +158 °F)
Environmental Rating
IEC IP65
Features
Safety protective field range: 3 m, 5.5 m
Warning field range: 40 m with remission of target = 90% (white)
Scanning angle: 275°
Detection capability: 40 mm, 70 mm
Scan cycle time: 30 ms
Response time: Programmable 62 to 482 ms
Tolerance zone max: 150 mm
Angular resolution: 0.1°
Zones sets: 6 Max
Vibration
According to IEC 61496-1 4.3.3.1 ; 5.4.4.1 ; IEC 60068-2-6
Frequency from 10 Hz to 55 Hz ; Scan Speed 1 octave/min
Range: 0.35 mm ± 0.05 mm
Shock
According to IEC 61496-1 4.3.3.2 ; 5.4.4.2
IEC 60068-2-29; Acceleration: 10 g; Pulse Duration: 16 ms; Number of
Shocks: 1000 ± 10 (for each of the three mutually perpendicular axes)
IEC 61496-3 5.4.4.1-3 ; IEC 60068-2-75 ; Hammer test
2.11.2 Dimensions
7
We recommend that you allow for a 15-minute warmup from a cold start.