For the avoidance of doubt, a 'qualified personnel', by possession of a recognized degree or certificate of professional
training, or by extensive knowledge, training and experience, has successfully demonstrated the ability to solve problems
relating to the installation of the scanner and its integration with the guarded machine. In addition to everything for which the
designated person in empowered, the qualified person is empowered to:
•
Install the scanner
•
Perform all scanner checkout procedures
•
Control the password to access the scanner's configuration settings
•
Reset the system following a lockout condition
•
Perform maintenance and repairs
With regards to window replacement, the qualified person shall be, among other things, responsible for:
•
Complying with the instructions set forth in this manual
•
Training the qualified operator accordingly
•
Carrying out the activities under your accountability in a proper way and in compliance with the instructions provided
herein
•
Maintaining the safe operation of the product and the environment in which it is installed
•
Abiding by all regulations and directives for labor protection and safety at work
•
Regularly having the product tested by competent persons, who shall report any anomalies and track the
performance of the product in written records.
By replacing the optical window, you declare to acknowledge and accept the potential risk and liabilities arising from the
window replacement procedure, as well as from failure to comply with the instructions provided by Banner in this respect. To
the fullest extent permitted by law, Banner (and its directors, officers and affiliates) shall not be held liable for any damages
(direct, indirect, or consequential) which might occur to you and any third parties as a consequence of the window
replacement procedure performed by you or your qualified personnel.
Note:
To perform the window replacement procedure, the following prerequisites must be strictly
observed.
•
Clean Environment: Avoid replacing the window in the field. The optical window must be replaced in a controlled,
pollution-reduced environment.
•
Non-Condensing Environment: The environment where the window replacement is performed must have temperature
of 18 - 30 °C and a non-condensing humidity (preferably less than 80%).
•
Free Area: A 2-meter (7-foot) free area around the 275° angle range of the scanner is necessary to calibrate and
validate the new optical window.
•
Visual Inspection: A visual inspection is needed before replacement to establish whether the optical window can be
replaced, or the entire scanner needs to be replaced instead.
•
Use of dedicated tools: To perform the window replacement procedure, a 2.5 mm hex key is necessary, preferably
with adjustable torque driver.
•
Skilled, authorized personnel: The replacement of the optical window must be performed by skilled, authorized
personnel only.
11.4.1 Replace Your Scanner's Window
After establishing that the replacement of the optical window is necessary and after making sure that all the prerequisites
have been met, start the window replacement procedure.
CAUTION:
Always disconnect power to the Safety Laser Scanner before starting the window replacement
procedure.
The new optical window replacement package contains the following parts:
•
One serialized optical window
•
One gasket seal
•
Four Tuflok
®
screws
CAUTION:
When handling the new optical window, avoid contaminating it with fingerprints, dirt, scratches,
dust, and polluting agents. It is recommended to wear clean, thin gloves to unpack and install the new
window.
1. Place the scanner on a flat surface in a controlled, pollution-reduced environment.
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767
119