Banner SureCross Performance GatewayPro Series Скачать руководство пользователя страница 8

Certifications

Included with Device ('Pro Models)

The following items ship with the 'Pro radios.

• BWA-HW-001: Mounting Hardware Kit, containing four M5-0.8 x 25mm SS screws, four M5-0.8 x 16mm SS screws, four M5-0.8mm

SS hex nuts, and four #8-32 x 3/4" SS bolts

• BWA-9O2-C (900 MHz) or BWA-2O2-C (2.4 GHz): Antenna, 2 dBd Omni, Rubber Swivel RP-SMA Male. (Not included with Internal

antenna models)

• Quick Start Guide (128185 for DX80 Gateways or 152653 for MultiHop models)
• MQDC1-506: 5-Euro (single ended) straight cable, 2m (Not included with FlexPower devices)
• BWA-EX2M: Ethernet crossover cable, M12 industrial/RJ45, 2 meter

Ethernet Cables

Part No.

Model No.

Description

77669

BWA-E2M

Ethernet cable, RSCD RJ45 440, 2M

78469

BWA-E8M

Ethernet cable, RSCD RJ45 440, 8M

78467

BWA-EX2M

Ethernet cable, crossover, RSCD RJ45CR 440, 2M

Use a crossover cable to connect the DX80 GatewayPro or DX83 Ethernet Bridge to a host system without using an Ethernet switchbox
or hub. When using a switchbox or hub, use a straight cable.

Warnings

The manufacturer does not take responsibility for the violation of any warning listed in this document.
Make no modifications to this product. Any modifications to this product not expressly approved by Banner Engineering could void the
user’s authority to operate the product. Contact the Factory for more information.
All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of prod-
ucts without notice. Banner Engineering reserves the right to update or change documentation at any time. For the most recent version of
any documentation, refer to our website: 

www.bannerengineering.com

©

 2006-2010 Banner Engineering Corp. All rights reserved.

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of
shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned
to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse,
abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (IN-
CLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND
WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL
BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPEN-
SES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY
PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WAR-
RANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or
liabilities relating to any product previously manufactured by Banner Engineering Corp.

 

 

SureCross Performance GatewayPro

 

www.bannerengineering.com - tel: 763-544-3164

 

Содержание SureCross Performance GatewayPro Series

Страница 1: ...to Banner Engineering s website www bannerengineering com surecross Models Power Frequency Feature DX80P9T6S P 10 to 30V dc 900 MHz ISM Band Modbus TCP or EtherNet IP communication protocol DX80P9A6S P Modbus TCP protocol Configuration capability using the Web Configu rator WARNING Not To Be Used for Personnel Protection Never use this product as a sensing device for personnel protection Doing so ...

Страница 2: ...e SureCross Performance GatewayPro combines in one unit the function of a SureCross Performance Gateway with the ability to interface to Ethernet using Modbus TCP or EtherNet IP protocols The GatewayPro has a serial port as well as an industrial Ethernet port There are two basic models of the GatewayPro DX80P T6 and DX80P A6 DX80P T6 The T6 model acts as a protocol converter only offering the Modb...

Страница 3: ... the black cover plate from the bottom of the device s cover The DIP switches are located behind the rotary dials After making the necessary changes to the DIP switches place the black cover plate back into position and gently push into place Plug the ribbon cable in after verifying that the blocked hole lines up with the missing pin Mount the cover back onto the housing DIP Switch Settings Switch...

Страница 4: ...r Node 1 are 17 through 32 as shown in the Modbus Holding Register table below Though only ten Nodes are shown the table can continue for as many Nodes as are used in a given network Using the equation or the Modbus Holding Registers table the register number for I O point 15 for Node 7 is 127 Modbus Holding Registers I O Point Gateway Node 1 Node 2 Node 3 Node 4 Node 5 Node 6 Node 7 1 1 17 33 49 ...

Страница 5: ... DX80 Outputs Instance 112 0x70 Words are not allocated for any specific unit but are used in device order for each of the device output registers selected using the EIP checkbox For proper EtherNet IP communication the minimum requested packet interval should be 150 milliseconds or higher Instance 100 Instance 112 Word Inputs Word Outputs 0 Input 1 0 Output 1 1 Input 2 1 Output 2 2 Input 3 2 Outp...

Страница 6: ...g the host s IP address open a web browser and log into the Ethernet Bridge GatewayPro or MultiHop Pro by typing the IP address in the browser location window http 192 168 0 1 After entering the IP address the home web page for the SureCross device displays To log in click on any tab at the top of the page To log out close the browser Admin level access allows administrators to set up system users...

Страница 7: ...on sulphur cured button covers Weight 0 26 kg 0 57 lbs Mounting 10 or M5 SS M5 hardware included Max Tightening Torque 0 56 N m 5 in lbf Antenna Connection Ext Reverse Polarity SMA 50 Ohms Max Tightening Torque 0 45 N m 4 in lbf Interface Indicators Two bi color LEDs Buttons Two Display Six character LCD Wiring Access One 5 pin Euro style male connector and One 4 pin fe male industrial Ethernet co...

Страница 8: ...t any time For the most recent version of any documentation refer to our website www bannerengineering com 2006 2010 Banner Engineering Corp All rights reserved Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Banner Engineering Corp will repair or replace free of c...

Отзывы: