Model No.
Description
Datasheet
QS30WEQ
WORLD-BEAM Photoelectric Emitter, QS30 (Max Range: 100
feet, 10x excess gain at 50 feet), 1-wire serial interface
QS30WRQ
WORLD-BEAM Photoelectric Receiver, QS30 (Max Range:
100 feet, 10x excess gain at 50 feet), 1-wire serial interface
M12FTH3Q
Temperature and Humidity Sensor, RS-485 Modbus inter-
face
M12FT3Q
Temperature Sensor, RS-485 Modbus interface
11.4 Other Sensors
Other sensors or sensor components include:
Model No.
Description
BWA-THERMISTOR-001
NTC Thermistor, 2 KOhms, +/-0.2%C
BWA-S612-30-100
NoShok Series 612 Submersible Level Transmitter, model 612-30-1-1-N-100, 0 to 30 psig,
100' cable
BWA-S612-15-100
NoShok Series 612 Submersible Level Transmitter, model 612-15-1-1-N-100, 0 to 15 psig,
100' cable
BWA-625-5000-1-1-8-25
NoShok Series 625 Intrinsically Safe Pressure Transmitter, model 625-5000-1-1-8-25, 0 to
5000 psig, 1/2" NPT,4–20mA, M12 QD
BWA-625-10000-1-1-8-2
5
NoShok Series 625 Intrinsically Safe Pressure Transmitter, model 625-10000-1-1-8-25, 0 to
10000 psig, 1/2" NPT, 4–20mA, M12 QD
BWA-P-RKGV
5.33T-1727-2.0
Cable, female M12 4-pin, blue PVC, SS connector, for NoShok Series 625 IS Pressure Trans-
mitter
BWA-ACC-SEN-SDI
Acclima SDI-12 Soil Moisture Transducer
11.4.1 Sensors with a Serial Interface
The following sensors are designed to be used with any of the 1-Wire Serial Interface FlexPower Nodes.
Sensors
Model No.
Description
Datasheet
M12FTH4Q
Temperature and Humidity Sensor, ±2% Accuracy, 1-wire
serial interface
M12FT4Q
Temperature Sensor with 1-wire serial interface
SureCross DX80 and Performance DX80 Product Manual
90
www.bannerengineering.com - tel: 763-544-3164
Rev. J