Страница 1: ...DXM1200 Bx Wireless Controller Instruction Manual Original Instructions p n 216539 Rev J July 27 2023 Banner Engineering Corp All rights reserved...

Страница 2: ...the Configuration File to the DXM Controller 18 Chapter 3 ISM Radio Board Slave ID 1 MultiHop Radio DIP Switches 19 Application Mode 20 Baud Rate and Parity 20 Disable Serial 20 Transmit Power Levels...

Страница 3: ...Controller 57 Define the Network Interface Settings 58 Configure your Ethernet Connection 58 Configure your Cellular Connection 59 Ethernet and Cellular Push Retries 59 Ethernet Push Retries 59 Cellu...

Страница 4: ...tification 900 MHz 1 Watt Radios 76 FCC Notices 77 FCC and ISED Approved Antennas 77 FCC and ISED Certification 2 4GHz 78 FCC Notices 78 FCC and ISED Approved Antennas 78 Mexican Importer 79 ANATEL 79...

Страница 5: ...Cross radios Programming language LED indicators Ethernet Scheduler Internal micro USB Push to the cloud RS 485 Client Data logging Modbus registers for internal local registers Modbus ID 199 Local R...

Страница 6: ...teway and Node radios Battery powered Node applications are more efficient in a star topology Six inputs and six outputs maximum per radio MultiHop Wireless Radio Network Tree topology between one cli...

Страница 7: ...housing One 4 pin M8 Ethernet connector One 5 pin M12 power and RS 485 connector E Extended housing One 4 pin M12 D Code Ethernet connector One 5 pin M12 power and RS 485 connector Custom products ar...

Страница 8: ...e DXM Configuration Software EtherNet IP The Ethernet port is actively running EtherNet IP From the factory the DXM Controller is configured to read and write registers on DX80 wireless devices 1 thro...

Страница 9: ...ss Controller may have up to three internal Modbus server devices DXM internal Modbus IDs factory default Modbus ID Device 1 DX80 Performance Gateway or MultiHop ISM Radio MultiHop wireless devices co...

Страница 10: ...ction manual p n 209933 The DXM Configuration Software configures the DXM Controller by creating an XML file that is transferred to the DXM Controller using an Ethernet connector or the internal micro...

Страница 11: ...1 DXM1200 Dimensions All measurements are listed in millimeters unless noted otherwise DXM1200 dimensions 148 1 mm 5 83 130 4 mm 5 13 140 8 mm 5 54 170 5 mm 6 71 147 9 mm 5 82 DXM1200E dimensions PG9...

Страница 12: ...Blank page 12...

Страница 13: ...escription 1 4 5 3 2 1 Brown bn 10 to 30 V DC 2 White wh RS485 D1 B 3 Blue bu DC common GND 4 Black bk RS485 D0 A 5 Gray gy Comms Ground IMPORTANT Never operate a 1 Watt radio without connecting an an...

Страница 14: ...io accepts data only from the client radio to which it is bound The binding code defines the network and all radios within a network must use the same binding code Apply power to all the devices Separ...

Страница 15: ...11 through 60 For MultiHop radios without rotary dials Use the DXM arrow keys to select the device ID to assign to the MultiHop radio about to enter binding mode The DXM assigns this device ID to the...

Страница 16: ...ration software For a more comprehensive explanation of features refer to the DXM Configuration Software Instruction Manual p n 209933 For a complete list of all associated product documentation go to...

Страница 17: ...a time 1 Select the range of registers to change 2 Select the fields to change in each local register In our example registers one through six will be changed and the names will be GPS Reg followed b...

Страница 18: ...l take a few seconds for the DXM Controller to reboot IMPORTANT If the power cycles to the DXM Controller while the DXM Configuration Software is connected close the USB port from the software and unp...

Страница 19: ...ISM radio For models with a LCD display use the ISM menu to bind the radio LED Operation The LED located on the ISM radio module indicates power and communications traffic ISM board LED operations al...

Страница 20: ...mode and DXM menu control for the radio power settings Application Mode The MultiHop radio operates in either Modbus mode or transparent mode Use the internal DIP switches to select the mode of opera...

Страница 21: ...evice To obtain Modbus register data from a MultiHop device configure the DXM Controller to access each device across the wireless network as an individual Modbus server device Example MultiHop Modbus...

Страница 22: ...1 16 are allocated for the Gateway the next 16 17 32 are allocated for Node 1 the next 16 33 48 are allocated for Node 2 and so forth There are no inputs or outputs on the DXM embedded Gateway but the...

Страница 23: ...Outputs in order by device 2201 through 4784 Discrete Bit Packed Status Discrete Inputs Discrete Outputs 6601 through 6753 Analog Inputs 1 8 and Analog Outputs 1 8 6801 through 9098 Input Registers a...

Страница 24: ...Node 32 Bit P acked Discrete Output1 Bit Position Register Address 15 14 13 12 11 10 6691 Node 15 Node 14 Node 13 Node 12 Node 11 Node 10 Node 9 Node 8 Node 7 Node 6 Node 5 Node 4 Node 3 Node 2 Node 1...

Страница 25: ...ng with register 6801 In this format users can read a 16 bit holding register for all devices or write to a register for all devices using one Modbus message Using these registers is the most efficien...

Страница 26: ...Blank page 26...

Страница 27: ...Internal Local Registers ID 199 for the DXM700 DXM1000 and DXM1200 29 Modbus RTU Client 32 DXM Controller base board ON 1 1 ON Button Micro USB LED 1 Status LED LED 2 Reserved Cellular Modem Connecto...

Страница 28: ...the board with the cellular modem s U FL connector as shown Only install remove a cellular modem when the power to the device is disconnected DIP Switch Settings for the Base Board After making change...

Страница 29: ...is not provided with the device Internal Local Registers ID 199 for the DXM700 DXM1000 and DXM1200 The main storage elements for the DXM Controller are its local registers which can store 4 byte value...

Страница 30: ...he configuration settings of the DXM Controller Do not use Read Rules to move virtual local registers data into local registers Use the Action Rule Register Copy function to move virtual local registe...

Страница 31: ...k 10113 Number of 43 buffer successes DX80 Gateway automatic messaging buffer statistics 10114 Number of 43 buffer timeouts 10115 Number of 43 buffer errors 10116 43 buffer success streak 11000 Read m...

Страница 32: ...devices As a Modbus RTU client device the DXM Controller controls external servers connected to the primary RS 485 port the local ISM radio local I O base board and the local display board Use the DXM...

Страница 33: ...July 27 2023 DXM1200 Bx Wireless Controller Instruction Manual 33 Settings General screen Banner Engineering Corp...

Страница 34: ...Blank page 34...

Страница 35: ...e 11 8 V DC Using the DXM Cellular Modem The DXM cellular modem provides a remote network connectivity solution for the DXM Controller To use the cellular modem Activating a Cellular Modem Follow thes...

Страница 36: ...1WW 001 Worldwide CAT M1 cellular modem using Telit ME910 model kit Includes a cellular modem SIM card internal adhesive antenna external SMA antenna and antenna cable The SIM card is specific to the...

Страница 37: ...of the cellular modem while ensuring the conductive pads on the SIM card are interfacing with the terminals of the modem There is a matching notch in the socket and SIM card that will only allow the...

Страница 38: ...gth of the housing b Slowly peel off the paper backing exposing the adhesive and stick to the plastic housing The antenna should run below the rim of the housing c Press firmly d Orient the cellular m...

Страница 39: ...ake up to 24 hours for the cellular plan to become active on the wireless network 6 Work with the local Banner technical support person to identify and purchase machine to machine M2M data plan only S...

Страница 40: ...Cellular screen If there are no webserver parameters defined the user must force a push to retrieve the data from the cellular network On the LCD menu select Push Trigger Data Push Obtaining LTE servi...

Страница 41: ...2023 DXM1200 Bx Wireless Controller Instruction Manual 41 Document title Install and Activate a Cellular Modem Part number 205026 Revision G Banner Engineering Corp All rights reserved Banner Engineer...

Страница 42: ...Blank page 42...

Страница 43: ...cal line with an arrow at the bottom if the user can scroll down to see more menu items The DXM can be configured to require a passcode be entered before the LCD and Menu system will operate The passc...

Страница 44: ...to accept ENTER CK to return to the previous menu Site Survey results OR Failed to start Site Survey The first option under the ISM Radio menu only displays the type of radio in the DXM Controller Mul...

Страница 45: ...lient MultiHop radio allocates a range of Modbus IDs for wireless devices typically 11 through 110 When setting the new ISM Modbus ID the system changes the Modbus ID on the internal radio and changes...

Страница 46: ...Subnet Mask to 255 255 255 255 Reboot the DXM Controller after changing the Ethernet parameters The Ethernet cable should be attached before powering up the DXM Controller LCD Contrast Use the LCD Co...

Страница 47: ...running LCD Board Displays the serial number model date firmware part numbers and version numbers Display Lock Display Lock protects the DXM LCD menu system from being used until the proper pass code...

Страница 48: ...Blank page 48...

Страница 49: ...d Local Registers Modbus ID 199 Processor Controller ISM Radio Modbus ID 1 User Display Modbus ID 201 Local Registers Integer Local Registers Float Local Registers Cellular Modem Control Gateway or Mu...

Страница 50: ...lower This is because all internal devices such as the ISM radio LCD etc of the DXM Controller are also Modbus servers Wireless and Wired Devices Wireless DX80 Performance Gateway The DX80 Performance...

Страница 51: ...04 seconds A MultiHop device is set from the factory with the retry parameter of 8 This means that under worst case conditions a message is sent from the DXM Controller to an end device a total of ni...

Страница 52: ...e DXM Controller Adjust the number of retries in the MultiHop devices by writing the number of retries desired to Modbus register 6012 The factory default setting is 8 Calculating the Communication Ti...

Страница 53: ...t contain tables with rows click on any row to select it Then click Clone or Delete to copy paste or remove that row Create a Weekly Event Use the Scheduler Weekly Events screen to define weekly event...

Страница 54: ...nfigured to require a login and password authentication Webserver Cloud Services Authentication Mail Server Authentication DXM Configuration Authentication The webserver and mail server authentication...

Страница 55: ...he DXM Controller must be connected to the PC to change the administration password From within the DXM Configuration Software go to the Settings Cloud Services screen 1 In the upper right select Show...

Страница 56: ...tion in a XML file Use the File menu to Save or Load configuration files Save the configuration file before attempting to upload the configuration to the DXM Controller The DXM Configuration Software...

Страница 57: ...neric device with the product name of Banner DXM ProdType 43 Generic Device ProdName Banner DXM Integer Type INT IMPORTANT Do not set the Requested Packet Interval RPI any faster than 150 ms Configuri...

Страница 58: ...gs On the Cloud Services screen shown with Show advanced settings selected define the network connection settings by selecting Ethernet or Cell from the Network Interface drop down list This determine...

Страница 59: ...t counted as failed attempts to send data Only when there is a good network connection and there are 10 failed attempts will the controller archive the data on the SD card Data archived on the SD card...

Страница 60: ...0 count limit For example if the cellular antenna is disconnected for period that the DXM controller would have sent 20 messages under normal circumstances all 20 messages would be saved and will be r...

Страница 61: ...h slots Modules have different functionalities Modules are plugged into slots In the PROFINET IO data model Slot 0 Subslot 1 is reserved for the Device Access Point DAP or network interface Configure...

Страница 62: ...Module sizes supported are 64 128 256 and 512 bytes Input Integers are data from the DXM to the PLC Output integers are data from the PLC to the DXM Slots 1 through 3 Module Notes Input Integer 512 A...

Страница 63: ...ll come from DXM Local Registers 1 through 320 Slot 2 Input Integer 128 Slot 4 Input Float 128 The input Floating register module has a total of 128 byes 64 Modbus registers Since it takes two Modbus...

Страница 64: ...s screen 6 Click Options and select Manage general station description file GSD The Install general station decription file window opens 7 Click the More options icon to the right of the Source path f...

Страница 65: ...d places it in the Hardware catalog In the example the DXM GSD file is located under Other field devices PROFINET IO Banner Engineering Corp Banner Launch the Siemens TIA Portal v14 software 1 Click O...

Страница 66: ...nline diagnostics Online diagnostics menu and screen The Online diagnostics windows displays 12 Select Assign IP address under Functions 13 Click Accessible devices The Select device window searches t...

Страница 67: ...using the LCD or software until after the PLC discovers the DXM and assigns it the specified address again However if this address is different than what is specified in the PLC the DXM reverts to the...

Страница 68: ...Blank page 68...

Страница 69: ...wer Supplies PSD 24 4 DC Power Supply Desktop style 3 9 A 24 V DC Class 2 4 pin M12 quick disconnect QD PSDINP 24 06 DC power supply 0 63 Amps 24 V DC with DIN Rail Mount Class I Division 2 Groups A B...

Страница 70: ...Blank page 70...

Страница 71: ...nd are only accessible by removing the SD card Data Log Files HTTP Push Files User created ScriptBasic file ScriptBasic program file CmVMon file _sxi Archive directory Data Log files Users may create...

Страница 72: ...called sav Update Your DXM Processor Firmware Using the DXM Configuration Software To update your processor firmware using the DXM Configuration Software follow these instructions After the file load...

Страница 73: ...e possible periodic firmware updates are released to enhance and expand the capabilities of the DXM Firmware updates and description details are found on the Banner website Customers with critical upd...

Страница 74: ...45 N m 4 lbf in Spread Spectrum Technology FHSS Frequency Hopping Spread Spectrum Link Timeout Performance Gateway Configurable via User Configuration Software Node Defined by Gateway Radio Packet Siz...

Страница 75: ...ing leads 24 AWG shall not be spliced For additional product support go to www bannerengineering com Supply Wiring AWG Required Overcurrent Protection A Supply Wiring AWG Required Overcurrent Protecti...

Страница 76: ...mm 5 13 140 8 mm 5 54 170 5 mm 6 71 147 9 mm 5 82 DXM1200E dimensions PG9 2 M12 x 1 M12 x 1 25 4 mm 1 20 1 mm 0 79 FCC and ISED Certification 900 MHz 1 Watt Radios This equipment contains transmitter...

Страница 77: ...rity SMA connectors with the antennas listed in Certified Antennas for 900 MHz 1 Watt on page 77 When integrated into OEM products fixed antennas require installation preventing end users from replaci...

Страница 78: ...f not a second label must be placed on the outside of the final device that contains the following text Transmitter Module DX80 2400 or SX243 Contains FCC ID UE300DX80 2400 or UE3SX243 Contains IC 704...

Страница 79: ...r Swivel DX80 2400 5 dBi 50 BWA 2O5 MA Omni full wave dipole NMO DX80 2400 4 5 dBi 50 BWA 2O6 A Omni Dome Box Mount DX80 2400 6 dBi 50 BWA 2O7 C Omni Coaxial Sleeve Swivel DX80 2400 7 dBi 50 Mexican I...

Страница 80: ...gain should be so chosen such that the equivalent isotropically radiated power EIRP is not more than that permitted for successful communication Consult with Banner Engineering Corp if the destination...

Страница 81: ...ions to this product without prior express approval by Banner Engineering Corp will void the product warranties All specifications published in this document are subject to change Banner reserves the...

Страница 82: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...