background image

Quick Start Guide

Ultrasonic Label Sensors for Detection of Clear Labels

This guide is designed to help you set up and install the SLU4 Slot Sensor. For complete information on programming, performance,

troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at 

www.bannerengineering.com

. Search for p/n 230091 to view

the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices.

WARNING:

• Do not use this device for personnel protection

• Using this device for personnel protection could result in serious injury or death.

• This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety

applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition.

Models

Model

Supply Voltage

Output Type

Connection

SLU4-PN-2M

12 V DC to 30 V DC

Bipolar NPN/PNP

1.8 m (6 ft) unterminated 5-wire PVC cable

SLU4-PN-Q8

Integral 5-pin M12 male quick-disconnect connector

SLU4-PN-Q7

Integral 4-pin M8 male quick-disconnect connector

SLU4-BM-Q7

Selectable NPN or PNP

Features and Indicators

1

3

4

2

5

1. Output indicator

2. Display

3. (GAP/2PT/DYN)(+)

4. (TEACH)(SELECT)

5. (MODE)(-)

Output Indicator

• Amber LED illuminates when outputs are ON

• Flashes when short circuit or overload detected

Display

Use the display to view menu options and other information.

Figure 1. Display in Run Mode

1

2

3

4

5

6

1. Signal strength

2. Contrast indicator (0 to 9)

3. Threshold number

4. Output in gap or on label

5. Button lock or unlock

6. Auto adjust on/off (AUTO)

Buttons

Use the sensor buttons to program the sensor.

(GAP/2PT/DYN)(+)

• Press and hold for 2 seconds to access and select

different TEACH methods

• Press to increase the contrast threshold value

• Scroll through settings in the menu

• Manually adjust the threshold number while in Run

mode

(TEACH)(SELECT)

• Press and hold for 2 seconds to initiate the TEACH

process

• Select settings in MENU options

(MODE)(-)

• Press and hold for 2 seconds to access the menu

• Scroll through settings in the menu

• Manually adjust the threshold number while in Run

mode

SLU4 Slot Sensor

 

 

Original Document

225944 Rev. B | 070-0702

9 September 2022

225944

Содержание SLU4

Страница 1: ... male quick disconnect connector SLU4 PN Q7 Integral 4 pin M8 male quick disconnect connector SLU4 BM Q7 Selectable NPN or PNP Features and Indicators 1 3 4 2 5 1 Output indicator 2 Display 3 GAP 2PT DYN 4 TEACH SELECT 5 MODE Output Indicator Amber LED illuminates when outputs are ON Flashes when short circuit or overload detected Display Use the display to view menu options and other information ...

Страница 2: ... White 3 Black 4 Blue Figure 5 M12 and cabled models bipolar with remote input Remote TEACH bu 3 bn 1 wh 2 bk 4 gy 5 12 30V DC Load Load Figure 6 M12 Male Connector 1 4 5 3 2 1 Brown 2 White 3 Blue 4 Black 5 Gray Sensor Setup Use the following images and instructions to program the sensor for use The default TEACH mode is Gap TEACH Gap TEACH The sensor sets a threshold based on the gap between two...

Страница 3: ...exceeds set time One Shot Outputs turn on for set time when triggered by input Debounce Output changes immediately when a change in detect state occurs Then a timer prevents the output from switching again until the timer expires This behavior occurs on both the leading and trailing edges of the object Figure 9 Output Timing Delays Output OFF Delay ON Delay Time 1 Shot ON OFF D D D D Debounce Time...

Страница 4: ...d IP65 Ambient Temperature 4 C to 50 C 39 F to 122 F Certifications RoHS compliant Banner Engineering Europe Park Lane Culliganlaan 2F bus 3 1831 Diegem BELGIUM Turck Banner LTD Blenheim House Blenheim Court Wickford Essex SS11 8YT Great Britain Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year fo...

Отзывы: