3.3.8 Interfacing an E-Stop Button or Interlocking Switch
EZ-SCREEN LS cascading models can connect electrical (hard) contacts from external devices, such as emergency stop
buttons and interlocking switches, by using an RDLS-8..D cordset. The cascade input may be used to monitor emergency
stop buttons, interlocked gates, or guards and meets or exceeds the requirements for OSHA/ANSI control reliability and up
to Category 4 PLe, per ISO 13849-1.
3.3.9 Remote Fixed Blanking
On cascade models, fixed blanking is available to, in effect, "disable" beams that would otherwise be continually blocked by
a stationary object. One or multiple areas within an EZ-SCREEN LS sensor pair may be "blanked out," with a minimum of
one beam between two blanked areas. The first sensing beam (CH1 synchronization beam) at the display end of sensor
must remain clear (cannot be blanked); any other beam may be blanked. All beams of a fixed blanked area must remain
blocked during operation in order for the OSSDs to remain ON.
The Remote Fixed Blanking feature can be used on an EZ-SCREEN LS cascade receiver as a stand-alone system or in a
cascaded system. A DELSEF-81D cordset used with a EZA-RBK-1 Remote Blanking Key Switch or a RDLS-8..D cordset
with a user-supplied switch and indicator provides a convenient means to program the blanked area. The remote
programming is effective on all receivers in the cascaded systems (for example, multiple areas can be blanked on different
sensor pairs). After programing, the DELSEF-81D cordset and EZA-RBK-1 Remote Blanking Key Switch can be removed
(with power OFF) and replaced by the terminator plug, an EZ-LIGHT (integral or remotely mounted), or an Emergency Stop/
Interlocking switch via a RDLS-8..D cordset.
3.3.10 Status Indicators
Status indicators on both the emitter and receiver are visible on each sensor's front panel.
Emitter
Bi-color red/green Status indicator
—shows whether power is applied, and
whether the emitter is in RUN mode (green) or Lockout condition (flashing
red) .
1-Digit Diagnostic Display
—indicates configuration or specific error
conditions.
Status Indicator
Diagnostic Display
Figure 11. Status Indicators—Emitter
Receiver
Bi-color red/green Status indicator
—shows system status:
• outputs are ON or OFF (green ON or red OFF), or
• the System is in Lockout condition (flashing red)
Amber RUN mode indicator
—shows system status:
• RUN mode (ON), or
• Lockout (OFF)
1-Digit Diagnostic Display
—indicates configuration or specific error
conditions, or the total number of blocked beams.
Bi-color red/green Alignment indicators
—show status of a group of beams
(+/- 35 mm of indicator) along the length of the exit window:
• aligned and clear (green ON), or
• blocked and/or misaligned (red ON),
• fixed blanked area (flashing green),
• lockout (all OFF), or
• Beam 1 (sync) is blocked (Alignment Indicator 1 is red and all others
are OFF).
Run Mode Indicator
Status Indicator
Diagnostic Display
Alignment Indicator(s)
Figure 12. Status Indicators—Receiver