5 System Installation
5.1 Installing the Software
1. Download the latest version of the software from
2. Navigate to and open the downloaded file.
3. Click
Next
to begin the installation process.
4. Confirm the software destination and availability for users and click
Next
.
5. Click
Next
to install the software.
6. Depending on your system settings, a popup window may appear prompting to allow BERNSTEIN Safety
Controller to make changes to your computer. Click
Yes
.
7. Click
Close
to exit the installer.
Open
BERNSTEIN Safety Controller
from the
Desktop
or the
Start Menu
.
5.2 Installing the Safety Controller
Do not exceed the operating specifications for reliable operation. The enclosure must provide adequate heat dissipation so
that the air closely surrounding the Safety Controller does not exceed its maximum operating temperature (see
Specifications and Requirements
5.2.1 Mounting Instructions
The Safety Controller mounts to a standard 35 mm DIN-rail track. It must be installed inside an enclosure rated IP54 due to
IEC (NEMA 3) or better. It should be mounted to a vertical surface with the vent openings at the bottom and the top to
allow for natural convection cooling.
Follow the mounting instructions to avoid damage to the Safety Controller.
To
mount
the SCR P Safety Controller:
1. Tilt the top of the module slightly backward and place it on the DIN rail.
2. Straighten the module against the rail.
3. Lower the module onto the rail.
To
remove
SCR P Safety Controller:
1. Push up on the bottom of the module.
2. Tilt the top of the module slightly forward.
3. Lower the module after the top rigid clip is clear of the DIN rail.
Important:
Administrative rights are required to install the Safety Controller drivers (needed for
communication with the controller).
Important:
Mount the Safety Controller in a location that is free from large shocks and high-amplitude
vibration.
CAUTION:
Electrostatic Discharge (ESD) can cause damage to electronic equipment. To prevent this,
follow the proper ESD handling practices such as wearing an approved wrist strap or other grounding
products, or touching a grounded object before handling the modules. See ANSI/ESD S20.20 for further
information about managing ESD.
Note:
To remove an expansion module, pull apart other modules on each side of the desired module to
free bus connectors.