12 Glossary
A
Automatic Reset
The safety input device control operation setting where the
assigned safety output will automatically turn on when all of its
associated input devices are in the Run state.
C
Change of State (COS)
The change of an input signal when it switches from Run-to-Stop
or Stop-to-Run state.
Closed-Open Debounce Time
Time to bridge a jittery input signal or bouncing of input contacts
to prevent nuisance tripping of the Controller. Adjustable from 6
ms to 100 ms. The default value is 6 ms (50 ms for mute
sensors).
Complementary Contacts
Two sets of contacts which are always in opposite states.
Concurrent
The setting that permits an indefinite signal disparity between
channels, without going into a fault condition.
D
Designated Person
A person or persons identified and designated in writing, by the
employer, as being appropriately trained and qualified to perform
a specified checkout procedure.
Diverse-Redundancy
The practice of using components, circuitry or operation of
different designs, architectures or functions to achieve
redundancy and to reduce the possibility of common mode
failures.
Dual-Channel
Having redundant signal lines for each safety input or safety
output.
F
Fault
A state of a device characterized by the inability to perform a
required function, excluding the inability during preventive
maintenance or other planned actions, or due to lack of external
resources. A fault is often the result of a failure of the device
itself, but may exist without prior failure.
H
Hard (Fixed) Guard
Screens, bars, or other mechanical barriers affixed to the frame of
the machine intended to prevent entry by personnel into the
hazardous area(s) of a machine, while allowing the point of
operation to be viewed. The maximum size of the openings is
determined by the applicable standard, such as Table O-10 of
OSHA 29CFR1910.217, also called a "fixed barrier guard."
M
Machine Response Time
The time between the activation of a machine stopping device and
the instant when the dangerous parts of the machine reach a safe
state by being brought to rest.
Manual reset
The safety input device control operation setting where the
assigned safety output will turn On only after a manual reset is
performed and if the other associated input devices are in their
Run state.
O
Off Signal
The safety output signal that results when at least one of its
associated input device signals changes to the Stop state. In this
manual, the safety output is said to be Off or in the Off state
when the signal is 0 V dc nominally.
On Signal
The safety output signal that results when all of its associated
input device signals change to the Run state. In this manual, the
safety output is said to be On or in the On state when the signal is
24 V dc nominally.
Open-Closed Debounce Time
Time to bridge a jittery input signal or bouncing of input contacts
to prevent unwanted start of the machine. Adjustable from 10 ms
to 500 ms. The default value is 50 ms.
XS/SC26-2 Safety Controller
115