10.3 Ethernet Cordsets
Cat5e Shielded Cordsets
Cat5e Crossover Shielded Cordsets
Length
STP07
STPX07
2.1 m (7 ft)
STP25
STPX25
7.62 m (25 ft)
STP50
STPX50
15.2 m (50 ft)
STP75
STPX75
22.9 m (75 ft)
10.4 Interface Modules
NOTE: External device monitoring (EDM) is required to be wired separately to the N.C. contacts to
comply with ISO 13849-1 categories and ANSI/OSHA control reliability; see
page 90.
IM-T-9 series interface modules have 6A output, 22.5 mm DIN-mount housing, removable (plug-in) terminal blocks, low
current rating of 1V ac/dc at 5 mA, high current rating of 250 V ac/dc at 6A. See datasheet p/n 62822 for more
information.
Model
Supply Voltage
Inputs
Safety Outputs
Output Rating
EDM Contacts
Aux. Outputs
IM-T-9A
24V dc
2 (dual-channel
hookup)
3 N.O.
6 amps
2 N.C.
—
IM-T-11A
2 N.O.
1 N.C.
10.4.1 Mechanically Linked Contactors
Mechanically Linked Contactors provide an additional 10 or 18 amp carrying capability to any safety system. If used, two
contactors per Safety Output pair are required for Category 4. A single OSSD output with 2 contactors can achieve
Category 3. The N.C. contacts are to be used in an external device monitoring (EDM) circuit.
NOTE: EDM is required to be wired separately to the N.C. contacts to comply with ISO 13849-1
categories and ANSI/OSHA control reliability; see
on page 90 .
Model
Supply Voltage
Inputs
Outputs
Output Rating
11-BG00-31-D024
24 V dc
2 (dual-channel hookup)
3 N.O. and 1 N.C.
10 amps
11-BF18C01-024
18 amps