14 Components and Accessories
14.1 Replacement Parts and Accessories
Model
Description
Applicable Product
SC-USB2
USB cable
XS/SC26-2, SC10-2
SC-XMP2
Programming tool for SC-XM2/3
XS/SC26-2, SC10-2
DIN-SC
DIN End Clamp
XS/SC26-2, SC10-2
SC-XM2
External memory drive for the XS/SC26-2
XS/SC26-2
SC-XM3
External memory drive for the SC10-2
XS/SC26-2, SC10-2
SC-TS2
Screw terminal blocks controller
XS/SC26-2
SC-TS3
Screw terminal blocks expansion module
XS/SC26-2
SC-TC2
Spring cage terminal blocks controller
XS/SC26-2
SC-TC3
Spring cage terminal blocks expansion module
XS/SC26-2
14.2 Ethernet Cordsets
Cat5e Shielded Cordsets
Cat5e Crossover Shielded Cordsets
Length
STP07
STPX07
2.1 m (7 ft)
STP25
STPX25
7.62 m (25 ft)
STP50
STPX50
15.2 m (50 ft)
STP75
STPX75
22.9 m (75 ft)
14.3 Interface Modules
See datasheet p/n 62822 and p/n 208873 and
on page 53 for more information.
Model
Input Voltage
Inputs
Safety Outputs
Aux. Outputs
Output Rating
EDM Contacts
IM-T-9A
24 V dc
2 (dual-channel
hookup)
3 N.O.
—
6 amps
2 N.C.
IM-T-11A
2 N.O.
1 N.C.
SR-IM-9A
3 N.O.
—
See datasheet for
specifications
SR-IM-11A
2 N.O.
1 N.C.
14.3.1 Mechanically Linked Contactors
Mechanically Linked Contactors provide an additional 10 or 18 amp carrying capability to any safety system. If used, two
contactors per Safety Output pair are required for Category 4. A single OSSD output with 2 contactors can achieve
Category 3. The N.C. contacts are to be used in an external device monitoring (EDM) circuit.
See
on page 53 for more information.
Model
Supply Voltage
Inputs
Outputs
Output Rating
11-BG00-31-D-024
24 V dc
2 (dual-channel hookup)
3 N.O. and 1 N.C.
10 amps
BF1801L-024
18 amps
XS/SC26-2 and SC10-2 Safety Controllers
154
www.bannerengineering.com - Tel: + 1 888 373 6767