Pulse Pro/PFM Settings
Available when Output Mode is set to
Pulse Pro/PFM
.
The K50R can generate pulses whose frequency are proportional to the sensor's measured distance, thereby
providing a method for representing an analog signal with only a discrete counter. The sensing range of the sensor
is scaled from 100 Hz to 600 Hz. An output of 50 Hz or 650 Hz (user defined in the software) represents a loss of
signal condition where there is no target or the target is out of range. This output can be tied directly to a number of
Banner lights for visual feedback without the need for a controller.
100 Hz:
Define one sensing range limit of the Pulse Pro range.
600 Hz
: Define another sensing range limit of the Pulse Pro range.
Loss–of–Signal
: Sets the value used by the sensor during a loss of signal. When a signal is restored, measurement
resumes.
Hold last value—The Discrete 2 Output holds the last value indefinitely during a loss of signal.
50 Hz—The Discrete 2 Output switches to this value 2 seconds after a loss of signal.
650 Hz—The Discrete 2 Output switches to this value 2 seconds after a loss of signal.
4.4.4 Indication Tab
Use this tab to configure advanced indications for Pro models with configurable LEDs.
See
on page 19 for details.
4.5 Live Sensor Data Controls
After connecting to the sensor, data sampling begins automatically (but not recording).
To stop data sampling, click
Stop
.
To restart data sampling, click
Play
. This only samples data from the sensor and displays it on the plot; it does not record
the data to a log file.
To record data to a log file, click
Record
. The log file selection prompt displays. Save the log file as desired. The log file
format is .csv.
If communication to the sensor is lost, click
Refresh Device Connection
to reconnect.