.02" diameter bifurcated fiber with threaded sensing end

Plastic Fiber Optic Assembly model PBT26U

PBT26U

     p/n 26080

This Banner plastic fiber is designed to be cut by the customer to the length required for the appli-
cation.  To facilitate cutting, a Banner model PFC-1 cutting device is supplied with this fiber.  
Cut the fiber as follows:
1)  Locate the "control end" of the fiber (the unfinished end).  Determine the length 
of fiber required for the application. At the control end of the fiber, separate the two 
fibers.  Lift the top (blade) of the cutter to open the cutting ports.  Insert one of the 
control ends through one of the two small cutting ports on the PFC-1 cutter so that the 
excess fiber protrudes from the back of the cutter.
2)  Double-check the fiber length, and close the cutter until the fiber is cut. Using a different 
cutting port, cut the second control end to the same length as the first.
3)  Gently wipe the cut ends of the fiber with a clean, dry cloth to remove any contamination.  
Do not use solvents or abrasives on any exposed optical fiber.  Do not use a cutting port more than once.  The blade 
may tend to dull after one cut.

PFC-1 Cutting Device

SENSING RANGE:  A function of the sensor. For further information, see the 

data sheet packed with the sensor, or refer to the Banner product catalog.
TEMPERATURE  EXTREMES:    Temperatures  below  -30°C  will  cause 

embrittlement of the plastic materials but will not cause transmission loss.  

Temperatures  above  +70°C  will  cause  both  transmission  loss  and  fiber 

shrinkage.
REPEAT BENDING/FLEXING:  Life expectancy of plastic fiber optic cable 

is in excess of one million cycles at bend radii of no less than the minimum 

(stated at right) and a bend of 90 degrees or less.  Avoid stress at the point where 

the cable enters the sensor ("control end") and at the sensing end tip.  Coiled 

plastic fiberoptic assemblies are recommended for any application requiring 

reciprocating fiber motion.
OPERATING TEMPERATURE: -30 to +70°C (-20 to +158°F).

CHEMICAL RESISTANCE:  The acrylic core of the monofilament opti-

cal fiber will be damaged by contact with acids, strong bases (alkalis) and 

solvents.  The polyethylene jacket will protect the fiber from most chemical 

environments.  However, materials may migrate through the jacket with long 

term exposure.  Samples of fiber optic material are available from Banner for 

testing and evaluation.
MINIMUM BEND RADIUS OF PLASTIC FIBER:  0.5 inch (12 mm)

 

CONSTRUCTION:  

OPTICAL FIBER: acrylic monofilament

PROTECTIVE JACKET:  black polyethylene

THREADED END TIP and hardware: nickel plated brass

Fiber Cutting Information

Additional Specifications

Printed in USA 

 

 

 

 

 

 

 

 

 

 

              p/n 03431L4B

Model PBT26U is a bifurcated plastic fiber optic assembly with an 

M3 x 0,5mm threaded nickel plated brass sensing end.

The PBT26U operates in the diffuse sensing mode. Sensing light is 
transmitted and received through the threaded sensing end. Objects 
are detected by the light they reflect back through the sensing end.  

Fiber core diameter is .02 inch. 
The PBT26U may be used with plastic fiber optic sensors from the 

following Banner sensor families: D12, OMNI-BEAM, MAXI-BEAM, VALU-BEAM, Q45, MINI-BEAM, and 

ECONO-BEAM.  See page 2 for further information.