System Installation
MM-TA-12B Muting Module
Instruction Manual
6
5
4
3
8
1
2
24V dc
0V dc
K2
Brown
Grn/Yel
Blue
S1
S2
S4
IM-T-9A
Black
White
Violet
Mute
Enable
Not
Connected
Orange
Org/Blk
Installation of transient (arc) suppressors across
the coils of MPCE1 and MPCE2 is recommended
(see Warning).
S3
Y2
Y1
K1
Y4
Y3
14
13
24
23
34
33
Machine
Control
Feedback (optional)
MPCE
2
MPCE
1
7
Figure 3-19. Generic hookup: interface module, one-channel EDM, Mute Enable
CAUTION . . .
Shock Hazard
Always disconnect all power from the MM-TA-12B Muting Module and the guarded machine before
making any connections or replacing any component. Use extreme caution to avoid electrical shock at
all times. Serious bodily injury or death could result.
WARNING . . .
Proper Wiring
The generalized wiring configurations shown are provided only to
illustrate the importance of proper installation. The proper wiring
of the MM-TA-12B Muting Module to any particular machine is
solely the responsibility of the installer and end user.
WARNING . . .
OSSD Interfacing
To ensure proper
operation, the MM-TA-12B
OSSD output parameters and
machine input parameters must
be considered when interfacing
the MM-TA-12B solid-state
OSSD outputs to machine
inputs. Machine Control circuit-
ry must be designed so that the
maximum load resistance value
is not exceeded and that the
maximum specified OSSD OFF-
state voltage does not result in
an ON condition. Failure to
properly interface the OSSD
outputs to the guarded machine
could result in serious bodily
injury or death.
WARNING . . .
Use of Transient
Suppressors
Transient suppressors are rec-
ommended. They MUST be
installed across the coils of the
machine control elements.
NEVER install suppressors
directly across the outputs of
the Module! It is possible for
suppressors to fail as a short
circuit. If installed directly
across the contacts of the
Safety Module, a short-circuit-
ed suppressor will create an
unsafe condition.