Banner MINI-ARRAY BASIC Скачать руководство пользователя страница 1

MINI-ARRAY

®

 BASIC Two-Piece Measuring

Light Curtain

Instruction Manual

Original Instructions
220750 Rev. B
25 October 2021

©

 Banner Engineering Corp. All rights reserved

220750

Содержание MINI-ARRAY BASIC

Страница 1: ...MINI ARRAY BASIC Two Piece Measuring Light Curtain Instruction Manual Original Instructions 220750 Rev B 25 October 2021 Banner Engineering Corp All rights reserved 220750...

Страница 2: ...d Sensor Degradation Operation 7 3 Installation 8 3 1 Emitter and Receiver Mounting 8 3 2 Emitter and Receiver Wiring 9 3 3 Optically Align the Components 10 4 Auto Streaming Control 11 5 Specificatio...

Страница 3: ...s device for personnel protection could result in serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications...

Страница 4: ...serial output feature see Auto Streaming Control on p 11 By default this automatically sends FBB First Beam Blocked and TBB Total Beams Blocked measurement data over the EIA 485 interface The system i...

Страница 5: ...he diagnostic LEDs Table 1 Emitter 1 Red Diagnostic LED LED Condition ON Solid OFF Flashing 5x per second Flashing 1x per second Red Sensor is functioning normally No power to emitter Receiver is remo...

Страница 6: ...stores the settings in non volatile memory Note Connect the sensor to the Sensor Configuration Software within 5 seconds after making a proper connection to an active power supply If the sensor is no...

Страница 7: ...9 Fault Detection and Sensor Degradation Operation If the receiver detects a permanently blocked channel such as from a failed LED in the emitter the amber diagnostic LED flashes at 2 Hz and the devic...

Страница 8: ...h flat washer 1 Mount the emitter and receiver in their mounting T nuts see Figure 4 on p 8 2 Position the red lenses of the two units directly facing each other The connector ends of both sensors mus...

Страница 9: ...C SYNC OUT1 OUT2 ALARM EIA 485 EIA 485 SHIELD SHIELD P S V P S V SYNC SYNC Receiver Emitter Load 1 Load 2 DC Power Supply to external EIA 485 device terminal no connection Receiver Output 1 OUT1 is an...

Страница 10: ...ensor 3 Rotate the emitter and or receiver as necessary to align them 4 Align the emitter and receiver until the receiver s green LED is on and the amber and red LED are off Note By default the MINI A...

Страница 11: ...ing begins all communications to the sensor fail because of an unavoidable data collision BAUD Rate Default setting 38400 The default BAUD rate can be changed by using the Banner Sensor Configuration...

Страница 12: ...4 Construction Aluminum housing with black anodized finish acrylic lens cover Operating Conditions 40 C to 70 C 40 F to 158 F 95 maximum relative humidity non condensing Controller Programming Via EIA...

Страница 13: ...itter MBR3016PX485SQ Receiver 752 mm 29 62 in 813 mm 32 0 in 837 mm 33 0 in 860 mm 33 9 in MBE3616Q Emitter MBR3616PX485SQ Receiver 905 mm 35 62 in 966 mm 38 0 in 990 mm 39 0 in 1013 mm 39 9 in MBE421...

Страница 14: ...w 5 Gray 6 Pink 7 Blue 8 Red 6 2 Anti Vibration Mounting Kits MSVM 1 4 anti vibration mounts M4 0 7 9 5 mm 8 M4 Keps nuts These mounts are made from BUNA N rubber and are more resistant to chemicals a...

Страница 15: ...and allow 30 rotation 6 8 mm 2 0 27 25 4 mm 1 0 10 2 mm 2 0 40 6 4 mm 0 25 4 8 mm 2 0 19 13 1 mm 0 52 57 2 mm 2 25 44 5 mm 1 75 3 mm 0 12 53 8 mm 2 12 24 6 mm 0 97 MAB MBK EB Includes 2 end cap brack...