Banner MBE3616Q Скачать руководство пользователя страница 1

MINI-ARRAY

®

 BASIC Two-Piece Measuring

Light Curtain

Instruction Manual

Original Instructions
220750 Rev. B
25 October 2021

©

 Banner Engineering Corp. All rights reserved

220750

Содержание MBE3616Q

Страница 1: ...MINI ARRAY BASIC Two Piece Measuring Light Curtain Instruction Manual Original Instructions 220750 Rev B 25 October 2021 Banner Engineering Corp All rights reserved 220750 ...

Страница 2: ...nd Sensor Degradation Operation 7 3 Installation 8 3 1 Emitter and Receiver Mounting 8 3 2 Emitter and Receiver Wiring 9 3 3 Optically Align the Components 10 4 Auto Streaming Control 11 5 Specifications 12 5 1 Emitter and Receiver Mounting Dimensions 12 6 Accessories 14 6 1 Cordsets 14 6 2 Anti Vibration Mounting Kits 14 6 3 Mounting Bracket Kit Optional 15 7 Product Support and Maintenance 16 7 ...

Страница 3: ...is device for personnel protection could result in serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications A device failure or malfunction can cause either an energized on or de energized off output condition 1 1 Models Emitter Model Receiver Model Array Length Y Overall Length Total Beams Sensor Scan Ti...

Страница 4: ... serial output feature see Auto Streaming Control on p 11 By default this automatically sends FBB First Beam Blocked and TBB Total Beams Blocked measurement data over the EIA 485 interface The system is pre configured for a straight scan optical pattern where each emitter channel fires only at its opposing receiver element see Figure 2 on p 5 The system can also be configured for an interlaced opt...

Страница 5: ...the diagnostic LEDs Table 1 Emitter 1 Red Diagnostic LED LED Condition ON Solid OFF Flashing 5x per second Flashing 1x per second Red Sensor is functioning normally No power to emitter Receiver is removed from the system One or more emitter optical channel s not working properly Table 2 Receiver 3 Diagnostic LEDs Green Red and Amber The combined status of the Green and Red LEDs provides a simple s...

Страница 6: ...r stores the settings in non volatile memory Note Connect the sensor to the Sensor Configuration Software within 5 seconds after making a proper connection to an active power supply If the sensor is not connected to the configuration software within 5 seconds after applying power the sensor goes into auto stream mode 2 7 System Self Diagnostics Output 2 can be configured for Alarm Health Status us...

Страница 7: ... 9 Fault Detection and Sensor Degradation Operation If the receiver detects a permanently blocked channel such as from a failed LED in the emitter the amber diagnostic LED flashes at 2 Hz and the device enters Sensor Degradation mode If Output 2 is configured for Alarm Health Status Output 2 is inactive OFF After the receiver detects a permanently blocked optical channel the receiver effectively i...

Страница 8: ...th flat washer 1 Mount the emitter and receiver in their mounting T nuts see Figure 4 on p 8 2 Position the red lenses of the two units directly facing each other The connector ends of both sensors must point in the same direction 3 Measure from one or more reference planes such as the floor to the same points on the emitter and receiver to verify their mechanical alignment If the sensors are posi...

Страница 9: ...NC SYNC OUT1 OUT2 ALARM EIA 485 EIA 485 SHIELD SHIELD P S V P S V SYNC SYNC Receiver Emitter Load 1 Load 2 DC Power Supply to external EIA 485 device terminal no connection Receiver Output 1 OUT1 is an open collector transistor switch rated at 30 V DC maximum 150 mA maximum It is protected against overload and short circuits Receiver Output 2 Alarm OUT2 ALARM is an open collector transistor switch...

Страница 10: ...sensor 3 Rotate the emitter and or receiver as necessary to align them 4 Align the emitter and receiver until the receiver s green LED is on and the amber and red LED are off Note By default the MINI ARRAY Basic sets the gain level on power up If the sticks are properly aligned but have marginal signal cycle the power to set the gain settings MINI ARRAY BASIC Two Piece Measuring Light Curtain 10 w...

Страница 11: ...ming begins all communications to the sensor fail because of an unavoidable data collision BAUD Rate Default setting 38400 The default BAUD rate can be changed by using the Banner Sensor Configuration Software Auto Stream Serial Protocol The serial communication follows the this data format 1 Start of Header 0xF4 2 Sensor Address 0x41 3 Command 0x64 4 Number of Data Bytes 0x04 in little endian for...

Страница 12: ...P54 Construction Aluminum housing with black anodized finish acrylic lens cover Operating Conditions 40 C to 70 C 40 F to 158 F 95 maximum relative humidity non condensing Controller Programming Via EIA 485 to Banner Sensors GUI software Emitter Receiver Range 2 m 6 5 ft Minimum Object Sensitivity Straight Scan Mode 38 1 mm 1 5 in Interlaced Mode 25 4 mm 1 in Application Notes The emitter and rece...

Страница 13: ...mitter MBR3016PX485SQ Receiver 752 mm 29 62 in 813 mm 32 0 in 837 mm 33 0 in 860 mm 33 9 in MBE3616Q Emitter MBR3616PX485SQ Receiver 905 mm 35 62 in 966 mm 38 0 in 990 mm 39 0 in 1013 mm 39 9 in MBE4216Q Emitter MBR4216PX485SQ Receiver 1057 mm 41 62 in 1118 mm 44 0 in 1142 mm 45 0 in 1165 mm 45 9 in MBE4816Q Emitter MBR4816PX485SQ Receiver 1210 mm 47 62 in 1271 mm 50 0 in 1295 mm 51 0 in 1318 mm 5...

Страница 14: ...low 5 Gray 6 Pink 7 Blue 8 Red 6 2 Anti Vibration Mounting Kits MSVM 1 4 anti vibration mounts M4 0 7 9 5 mm 8 M4 Keps nuts These mounts are made from BUNA N rubber and are more resistant to chemicals and oils MAVM 1 4 anti vibration mounts M4 0 7 9 5 mm 8 M4 Keps nuts These mounts are made from natural rubber which are less chemically resistant than the MSVM 1 mounts but have a greater sheer forc...

Страница 15: ...lts and allow 30 rotation Ø 6 8 mm 2 Ø 0 27 25 4 mm 1 0 10 2 mm 2 0 40 6 4 mm 0 25 4 8 mm 2 0 19 13 1 mm 0 52 57 2 mm 2 25 44 5 mm 1 75 3 mm 0 12 53 8 mm 2 12 24 6 mm 0 97 MAB MBK EB Includes 2 end cap brackets Includes 4 screws M4 x 0 7 x 10 mm for Mini Array Basic End cap mounting 4 bolts mounting hardware M4 x 0 7 x 14 mm for customer 4 M4 nuts 8 Flat washers 8 Split washers MINI ARRAY BASIC Tw...

Страница 16: ... IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA...

Отзывы: