Table 68: TG (Ident 0x1) / Color (Ident 0x3) Device Control Submodule
PLC Input Data Name
Input Data Type
Device Control ACK Word
Unsigned16
Return Error Code
Unsigned32
Device Control ACK Word
Bit Position for Cyclic Input Data
Function
Bit 0
Product Change
Acknowledgement
Bit 1
Teach Latch Acknowledgement
Bit 2
Trigger Acknowledgement
Bit 13
Teach Error
Bit 14
System Error
Bit 15
Command Execution Error
PLC Output Data Name
Output Data Type
Device Control Command Word
Unsigned16
Product Change Number
Unsigned32
Device Control Command Word
Bit Position for Cyclic Output Data
Function
Bit 0
Product Change Request
Bit 1
Teach Latch Request
Bit 2
Trigger Request
Sensor Output Submodules
The Default Map Submodule contains sensor output data. This user-enabled submodule is optional and plugged into Slot 2
Subslot 1.
Table 69: Default Map Submodule (Ident 0x00027)
PLC Input Data Name
Input Data Type
Frame Number
Unsigned32
Sensor Type
Unsigned16
38-byte Sensor-specific Data Block
38-byte OctetString
Sensor Type
Unsigned16
38-byte Sensor-specific Data Block
38-byte OctetString
Sensor Type
Unsigned16
38-byte Sensor-specific Data Block
38-byte OctetString
Sensor Type
Unsigned16
38-byte Sensor-specific Data Block
38-byte OctetString
Sensor Type
Unsigned16
38-byte Sensor-specific Data Block
38-byte OctetString
PLC Output Data Name
Output Data Type
Not applicable
Not applicable
The 38-byte sensor-specific Data Block for each sensor type is shown below.
Table 70: Area Sensor ID = 2
Sensor-Specific Data
Data Size
Area Count
32
‐
bit Integer
Area Range Minimum
32
‐
bit Integer
Area Range Maximum
32
‐
bit Integer
iVu Plus TG and Color Gen2 Image Sensors
www.bannerengineering.com - Tel: + 1 888 373 6767