COLOR_AREA_HISTORY Command Group
Command
Group
Item
Description
Get
COLOR_AREA_HIS
TORY
MinCount
The minimum number of detected areas of a specific color since the
history was last cleared.
Get
COLOR_AREA_HIS
TORY
MaxCount
The maximum number of detected areas of a specific color since the
history was last cleared.
Get
COLOR_AREA_HIS
TORY
MinArea
The minimum detected area value of a specific color since the history
was last cleared.
Get
COLOR_AREA_HIS
TORY
MaxArea
The maximum detected area value of a specific color since the history
was last cleared.
Examples
>>
get color_area_history <ColorArea2> mincount
\x0D\x0A
<<
OK\x0D\x0A
<<
14\x0D\x0A
>>
get color_area_history <ColorArea2> minarea
\x0D\x0A
<<
OK\x0D\x0A
<<
10\x0D\x0A
14.4.5 Multiple Sensors in an Inspection
If there is more than one sensor in the inspection, all SensorType_Result and SensorType_History related commands must
include the
Sensor Name
in "< >" brackets.
Examples
>> get area_result <Area1> count\x0D\x0A
<< OK\x0D\x0A
<< 7665\x0D\x0A
Notice that <Area1> is the sensor name of an Area sensor in the current inspection.
>> get blemish_history <Blemish1> minedgelength\x0D\x0A
<< OK\x0D\x0A
<< 22\x0D\x0A
Notice that <Blemish1> is the sensor name of a Blemish sensor in the current inspection.
14.4.6 Command Channel Command Status Register
The command status register will confirm receipt of a command by reflecting the exact command ID received, regardless of
whether the command was valid or not.
14.4.7 Command Channel Error Codes
Table 20: iVu Command Channel Error Codes
Numeric ID
Text ID
Description
00000
SUCCESS
Command processed successfully
10000
EMPTY_FRAME_RECEIVED
Indicates that the request was empty. The command channel
requires a command, any arguments, and an end-of-frame
delimiter.
10001
COMMAND_NOT_RECOGNIZED
The command specified is not recognized
10100
GROUP_MISSING
A Group ID must be specified immediately after the command
10101
GROUP_NOT_FOUND
The specified Group ID is invalid / unknown