Figure 37. Reset to Defaults Screen
11.3 System Information
Main Menu > System > Information
The Information screen displays device information:
• Serial Number
• Firmware Version
• Boot Number
• Up Timer—the time elapsed since last boot up of the device
• Hour Count—the total hours of operation in the device's lifetime
• Model Number
• Device Name
Click the right-arrow next to Device Name to display a keyboard that allows you to change the name of the device.
11.4 Lock
device
Main Menu > System > Lock device
Lock the device to prevent accidental modification of settings. When locked, the device only provides access to pass/fail
statistics, as well as the ability to view logs and to save them to a USB device. A lock icon in the upper left corner of the
display indicates that the device is locked.
The device can be locked with or without a password. If a password is not used, click Unlock device to unlock the device.
When a password is used, it must be 4 digits entered using the keypad. If the password is lost, contact Banner Engineering
to obtain a Reset Key.
Note: This menu option is not available in the Emulator.
11.5 Communications Menu
Main Menu > System > Communications
Use the Communications menu to configure the serial I/O channel. There are six menu options:
• Ethernet I/O for configuring the Ethernet port
• Serial I/O for configuring the Serial port
• Industrial Ethernet settings
• Command Channel for sending commands to get specific data through Serial or Ethernet channels.
• Data Export Channel for enabling or disabling the channel for data export only
• Image Export Channel for enabling or disabling the channel for image export only
Note: Serial I/O can be configured either for Data Export or Command Channel. Image Export is only
available on Ethernet.
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767
55