May 22, 2023
EZ-SCREEN SLS Safety Light Curtain Instruction Manual
64
SCREEN SLS
automatically enters Alignment mode, and the receiver looks for an optical sync pattern from the emitter. If the
receiver is aligned and receives the proper sync pattern, it begins scanning to determine the blocked or clear status of each
beam. When all beams are aligned, the Yellow Reset indicator double-flashes to indicate the
EZ-SCREEN SLS
is waiting for
a manual reset. After a valid manual reset, the
EZ-SCREEN SLS
enters Run mode and continues scanning.
Trip Output Configuration
—If any beams become blocked while the
EZ-SCREEN SLS
is running with Trip Output selected,
the receiver outputs turn OFF within the stated
EZ-SCREEN SLS
response time (see
beams then become clear, the receiver outputs come back ON. No resets of any kind are needed. All required machine con-
trol resets are provided by the machine control circuit.
Latch Output Configuration
—If any beams become blocked while the
EZ-SCREEN SLS
is running with Latch Output select-
ed, the receiver outputs turn OFF within the stated
EZ-SCREEN SLS
). If all
the beams then become clear, the receiver Zone indicators will all be Green and the Reset indicator will single-flash, indicat-
ing the
EZ-SCREEN SLS
is waiting for a manual latch reset. In Latch Output operation, the outputs come back ON only when
all beams are clear and after a manual reset. The
EZ-SCREEN SLS
will wait for a manual reset; when a valid reset signal is
received and all beams remain clear, the receiver outputs turn ON.
Internal Faults (Lockouts)
—If either sensor detects a critical fault, scanning ceases, the receiver outputs turn OFF and diag-
nostic information is displayed through the sensor’s front window. See
for resolution of error/
fault conditions.
To ensure continued reliable operation, the System must be checked out periodically. Banner Engineering highly recom-
mends performing the System checkouts as described below. However, a Qualified Person should evaluate these recom-
mendations, based on the specific application and the results of a machine risk assessment, to determine the appropriate
content and frequency of checkouts.
At every shift change, power-up, and machine setup change,
the Daily Checkout should be performed; this checkout may be
performed by a Designated or Qualified Person.
Semi-annually,
the System and its interface to the guarded machine should be thoroughly checked out; this checkout must be
performed by a Qualified Person (see
). A copy of these test results should be posted on
or near the machine.
Whenever changes are made to the System
(either a new configuration of the
EZ-SCREEN SLS
System or changes to the
machine), perform the Commissioning Checkout (see
).
Verify Proper Operation The
EZ-SCREEN SLS
can operate as it is designed only if it and the guarded machine are operating
. Failure to correct such problems can result in an increased risk of harm. Before the System is
put back into service, verify that the
EZ-SCREEN SLS
System and the guarded machine perform exactly as outlined in the
checkout procedures and any problem(s) are found and corrected.
Run Mode
6.5.2
Periodic Checkout Requirements
6.6
© Banner Engineering Corp.
Содержание EZ-SCREEN SLS
Страница 16: ...May 22 2023 EZ SCREEN SLS Safety Light Curtain Instruction Manual 16 Banner Engineering Corp...
Страница 52: ...Blank page 52...
Страница 68: ...Blank page 68...
Страница 90: ...Blank page 90...
Страница 102: ...Blank page 102...
Страница 106: ...Blank page 106...
Страница 114: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...