May 22, 2023
EZ-SCREEN SLS Safety Light Curtain Instruction Manual
32
Emitter/receiver pairs with 14 mm (0.55 in) resolution may be spaced from 0.1 m to 6 m (4 in to 20 ft) apart. Emitter/receiver
pairs with 30 mm (1.18 in) resolution may be spaced from 0.1 m to 18 m (4 in to 60 ft) apart. The maximum distance between
an emitter and its receiver is reduced if corner mirrors are used (see
). The supplied
brackets allow ±30° rotation, when mounted to the sensor end caps.
From a common point of reference, ensuring the Safety Distance (Minimum Distance) calculated in
Distance (Minimum Distance)" on page 22
, make measurements to locate the emitter and receiver in the same plane, with
their midpoints and display ends directly opposite each other.Mount the emitter and receiver mounting brackets using the
supplied M6 bolts and Keps nuts, or user-supplied hardware.
The connector ends of both sensors must point in the same direction (see
Mount the emitter and receiver in their brackets; position their windows directly facing each other. Measure from a reference
plane (for example, a level building floor) to the same point(s) on the emitter and receiver to verify their mechanical align-
ment. Use a carpenter’s level, a plumb bob, or the optional LAT-1 Laser Alignment Tool (see
check the diagonal distances between the sensors to achieve mechanical alignment. Final alignment procedures are ex-
plained in
"Initial Checkout Procedure" on page 35
Center mounting brackets
must be used with longer sensors if they are subject to shock or vibration. In such situations, the
sensors are designed to be mounted with up to 900 mm (35.43 in) unsupported distance (between brackets). Sensors 1050
mm (45.33 in) and longer are supplied with a center bracket to be used as needed with the standard end-cap brackets.
End-Cap Brackets
(supplied with each emitter and receiver)
Swivel Center Bracket
(supplied with emitters
and receivers 1050 mm and longer)
End-Mounted
Side-Mounted (two sensor brackets
may be substituted)
Mounting the Emitter and Receiver
5.3
Attach the center bracket to the mounting surface when mounting the end-cap brackets.
1.
Attach the clamp to both slots of the housing, using the included M5 screws and T-nuts.
2.
After the sensor is mounted to the end-cap brackets, attach the clamp to the center bracket using the supplied M5
screw.
3.
Sensor brackets
Figure 13.
© Banner Engineering Corp.
Содержание EZ-SCREEN SLS
Страница 16: ...May 22 2023 EZ SCREEN SLS Safety Light Curtain Instruction Manual 16 Banner Engineering Corp...
Страница 52: ...Blank page 52...
Страница 68: ...Blank page 68...
Страница 90: ...Blank page 90...
Страница 102: ...Blank page 102...
Страница 106: ...Blank page 106...
Страница 114: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...