![Banner DXMR90-X1 Series Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/banner/dxmr90-x1-series/dxmr90-x1-series_instruction-manual_3746186042.webp)
May 09, 2023
DXMR90-X1 Series Controller Instruction Manual
42
If the DXM GSD file does not install properly, save the log and contact Banner Engineering Corp.
Change the Device IP Address
Follow these instructions to change the IP address of the DXM device using the Siemens TIA Portal (v14) software. Use
these instructions as a basis if you are using another controller (PLC).
The system installs the DXM GSD file and places it in the
Hardware catalog
. In the example, the DXM GSD file is lo-
cated under
Other field devices
›
PROFINET IO
›
Banner Engineering Corp.
›
Banner
.
Launch the Siemens TIA Portal (v14) software.
1.
Click
Open existing project
.
2.
Select a project and open it.
3.
Click
Devices & networks
.
Network view
The
Network view
displays.
4.
Double-click on the DXM icon to open the
Device view
screen.
5.
Click on the DXM icon in the graphic area of the
Device view
screen.
The
Module properties
window displays and the module can now be configured.
6.
Click
Properties
.
7.
Click
General
.
8.
Select
PROFINET Interface
›
Ethernet addresses
.
Ethernet addresses
9.
Select
Set IP address in the project
.
10.
Enter the IP address.
11.
Right-click on the device icon and select
Online & diagnostics
.
12.
© Banner Engineering Corp.
Содержание DXMR90-X1 Series
Страница 4: ...Blank page 4...
Страница 10: ...Blank page 10...
Страница 18: ...Blank page 18...
Страница 24: ...May 09 2023 DXMR90 X1 Series Controller Instruction Manual 24 Slave Port 0 Settings Banner Engineering Corp...
Страница 48: ...Blank page 48...
Страница 55: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...