Program Mode 

Program (PRG) mode allows the following set-
tings to be programmed in the DF-G1 :

Factory Default Settings:

Setting

Factory Default

Threshold

2026

TEACH Selection

Two-Point TEACH

Response Speed

Standard - 500 us

Offset Percent

10%

Auto Thresholds

OFF

OFF Delay

0 (Disabled)

OFF One-Shot

0 (Disabled)

ON Delay

0 (Disabled)

ON One-Shot

0 (Disabled)

Display Readout

Numeric, ECO disa-
bled, Normal Orien-
tation

Gain Selection

Auto Gain

 

 

DF-G1 - Expert Fiber Amplifier Install Sheet

 

 

P/N 161275 Rev. A

www.bannerengineering.com - tel: 763-544-3164

3

Содержание DF-G1 Expert

Страница 1: ...Q7 Single NPN Integral M8 Pico QD connector 4 pin DF G1 PS Q7 Single PNP Cordset Options A model with a QD connector requires a mating cordset For 9 m cable change the suffix 2M to 9M in the 2 m mode...

Страница 2: ...he output is ON when the sensing condition is outside the window SET Rocker Button The SET rocker button is a 3 way button The positions are engaged by rocking the button left right The SET position i...

Страница 3: ...ettings Setting Factory Default Threshold 2026 TEACH Selection Two Point TEACH Response Speed Standard 500 us Offset Percent 10 Auto Thresholds OFF OFF Delay 0 Disabled OFF One Shot 0 Disabled ON Dela...

Страница 4: ...Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment the GREEN display will flash 3 times to con firm Slide Mode switch to RUN to complete...

Страница 5: ...d signal Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 3 Dynamic TEACH Light Operate shown SET Button 0 04 seconds Click 0 8 seconds...

Страница 6: ...t Moves sensing window center value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode Press to increase press to decrease GREEN display shows the sensing window center value...

Страница 7: ...ration Remember Manual adjustments are disabled when Auto Thresholds are ON Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable offset below the presented condition...

Страница 8: ...switching threshold value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds...

Страница 9: ...bration SET Sensor positions threshold exactly at the presented condition Threshold position adjusted by Manual Adjust Darkest no signal Most Light saturated signal Output OFF Output ON Condition Pres...

Страница 10: ...ed Threshold Error The threshold s cannot be optimized and the sensor s output will stop functioning Cleaning correcting the sensing environment and or a re teach of the sensor is required Specificati...

Отзывы: