4.4 Environmental properties
4.4.1 Temperature monitoring
Sensors monitor temperature values at various areas in the PPC1200. For the position of temperature sensors, see
section
"Temperature sensor positions" on page 32
. The values specified there represent the defined maximum
temperature at this measuring point. If the temperature is exceeded, no alarm is triggered.
Temperatures
1)
can be read out in different ways in approved operating systems:
•
BIOS (see
)
•
ADI Control Center
•
ADI Development Kit
•
ADI .NET SDK
•
B&R HMI Service Center
•
B&R HMI Report
The CFast cards available from B&R are equipped with S.M.A.R.T support
2)
. Various parameters (e.g. temperature)
can be read out in approved Microsoft Windows or B&R Linux operating systems.
4.4.2 Temperature sensor positions
B
A
ADI sensors
Position Measuring
point for
Measurement
Max. specified [°C]
System unit sensor 1
A
CPU/RAM
Temperature of the processor area
5PPC1200.0702-xxx:
100
5PPC1200.101E-xxx:
95
5PPC1200.121E-xxx:
95
5PPC1200.156B-xxx:
95
System unit sensor 2
B
CFast
Temperature of the CFast area
5PPC1200.0702-xxx:
100
5PPC1200.101E-xxx:
95
5PPC1200.121E-xxx:
95
5PPC1200.156B-xxx:
95
1)
The measured temperature is a guide value for the immediate ambient temperature, but it may have been influenced by neighboring components.
2)
Self-Monitoring, Analysis and Reporting Technology
32