Technical data • Individual components
82
Panel PC 800 User's Manual V1.30
POWERLINK card 2 connections
Cabling
S/STP (Cat 5e)
Cable length
Max. 100 m (min. Cat 5e)
Speed LED
On
Off
Green/Red
See Status/Error LED.
Link LED
On
Off
Yellow
Link (POWERLINK net-
work connection available)
Activity (blinking - da-
ta transfer in progress)
Female RJ45 connector
1
Speed LED
Link LED
Table 57: 5ACPCC.MPL0-00 - POWERLINK interface
3.8.4.3.2 LED status indicators
The Status/Error LED is a green and red dual LED. The LED status can have different meanings depending on
the operating mode.
Ethernet TCP/IP mode
The interface can be operated purely as an Ethernet TCP/IP interface.
Green - Status
Description
On
POWERLINK interface operating purely as an Ethernet TCP/IP interface
Table 58: Status/Error LED - Ethernet TCP/IP operating mode
POWERLINK V1
LED status indicators
Green
Red
Status of the POWERLINK station
On
Off
The POWERLINK station is running with no errors.
Off
On
A fatal system error has occurred. The error type can be read using the PLC logbook. An irreparable problem has
occurred. The system cannot properly carry out its tasks. This state can only be changed by resetting the module.
Blinking alternately
The POWERLINK managing node has failed. This error code can only occur when operated as a controlled node.
Off
Blinking
System failure. The red blinking LED signals a certain type of error using a blink code (see section "System failure
Table 59: Status/Error LED - POWERLINK V1 operating mode
POWERLINK V2
Red - Error
Description
On
The POWERLINK interface has encountered an error (failed Ethernet frames, increased number of collisions on
the network, etc.).
If an error occurs in the following states, then the green LED blinks over the red LED:
•
BASIC_ETHERNET
•
PRE_OPERATIONAL_1
•
PRE_OPERATIONAL_2
•
READY_TO_OPERATE
t
t
t
"S/E" LED
Status
Green
Error
Red
Table 60: Status/Error LED as Error LED - POWERLINK V2 operating mode