Software • B&R Automation Device Interface (ADI) - Control Center
254
Panel PC 800 User's Manual V1.30
11.4 UPS configuration
This window displays the status values for an optionally installed B&R add-on UPS and allows the battery settings
for the UPS to be edited, updated and backed up. It is also possible to configure the system settings for the UPS.
Figure 136: ADI Control Center - UPS settings
Caution!
The installed UPS must be selected and configured in the Power Options section of the Control Panel
in order for battery operation to be supported.
Information:
The UPS service is supported in B&R Windows Embedded Version 2.10 and higher.
11.4.1 Installing the UPS service for the B&R add-on UPS
1. Open the
Control Center
in the
Control Panel
.
2. Select the
UPS
tab.
3. Under
UPS settings
, click on
System
. This opens the
Power options
in the Control Panel (
Power options
can also be opened directly from the
Control Panel
).
4. Go to the
UPS
tab and click
Select
.
5. Select "Ber Rainer" as the manufacturer and "APC add-on UPS" as the model and then click
Finish
.
The value for the COM connection is only required for a serially connected UPS and is ignored by the APC
add-on UPS driver.
6. Click on
Apply
to start the UPS service. The UPS status and details will be displayed after a few seconds.
7. Click
OK
.
The text field next to
System
(on the
UPS
tab in the
Control Center
) also indicates whether the B&R UPS driver
is active.
Information:
Administrator rights are required in order to change the energy options or display the UPS status.
11.4.2 Displaying UPS default values
1. Open the
Control Center
in the
Control Panel
.
2. Select the
UPS
tab.