Commissioning
Mobile Panel 7200 User's manual V 1.01
39
3. Loosen the gray screw nut
(1)
and the strain relief
(2)
from the attachment cable. The gray screw nut is then
no longer required.
4. Insert the attachment cable into the MP7200 through the intended opening. A corresponding screw thread
for securing the attachment cable is integrated in this opening.
5. Secure the bushing with a size 19 wrench and a torque of 3 Nm.
6. Insert the main connector and RJ45 connector into the intended female connectors. It is important to ensure
that the connectors are connected and engaged correctly, see
"Installing cables in the attachment shaft" on
7. Secure the strain relief with the wrench. There should still be several millimeters overlap of the cable jacket
inside the housing. It is important to ensure that the rubber ring for the strain relief is correctly positioned
under the bushing.
8. Install the cover with the Torx screws (torque: 0.8 to 1.0 Nm).
✓
The attachment cable is installed and meets the degree of protection requirements.
3.3.1 Notes about compliance with the degree of protection
The following points must be observed to ensure that the degree of protection is maintained for the MP7200.
•
The gaskets of the device are not permitted to be contaminated or damaged. If necessary, clean or replace
the gaskets with suitable cleaning agents.
•
Cables are not permitted to be pinched. This can result in damage to the cable as well as loss of leak
tightness.
•
All screws on the device must be installed and tightened. Otherwise, the device cannot be completely
sealed. This must also be observed when the unit is not in operation or during storage and transport.