Technical data
Mobile Panel 7200 User's manual V 1.01
29
2.3.2.2 Control cabinet cables
2.3.2.2.1 5CAMPC.0020-10
2.3.2.2.1.1 General information
A crossover control cabinet cable is required for the wiring inside the control cabinet.
The pinout of the Ethernet connector (crossover) makes it possible to connect directly to a B&R controller (e.g.
X20CPxxxx). For other devices, e.g. Ethernet hubs, it is important to ensure that they support crossover of the
RX and TX lines.
Information:
The control cabinet cable is used for all Mobile Panel product series. Not all wires are used when wiring
the MP7x00 and MP40/50. Functionality therefore differs from MP100/200 devices.
The surface is protected against water, oil (lubricating and hydraulic oils per EN 60811 Part 2-1) and cooling
lubricant.
The control cabinet cable is secured to the control cabinet door via the connection housing (see
). The other end of the control cabinet cable has a pre-assembled RJ45 Ethernet
connector. The remaining lines have an open end with wire end sleeves to make it easier to wire to safety equipment
and other interfaces.
2.3.2.2.1.2 Order data
Model number
Short description
Figure
Control cabinet cables
5CAMPC.0020-10
Mobile Panel control cabinet cable - Push-Pull circular connector
- Ethernet crossover - 2 m
Optional accessories
Accessories
4MPCBX.0000-00
Mobile Panel connection box - For cables with push-pull circular
connectors
4MPCBX.0001-00
Mobile Panel small connection box - For cables with push-pull
circular connectors
Table 5: 5CAMPC.0020-10 - Order data
2.3.2.2.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for these individual
components and may differ from those of the complete system. The data specified for the complete
system applies to the complete system in which this individual component is used, for example.
Model number
5CAMPC.0020-10
General information
Certifications
CE
Yes
UL
cULus E115267
Industrial control equipment
Cable construction
Type
Crossover
Supply lines
Conductor resistance
≤30 Ω/km
Material
Tinned copper stranded wire
Permissible operating voltage
30 VDC
Outer jacket
Material
Silicone- and halogen-free, flame-retardant PUR outer jacket
Color
Similar to RAL 7012
Table 6: 5CAMPC.0020-10 - Technical data