Commissioning
Mobile Panel 7100 User's manual 1.51
73
Attachment shafts 5MP7150.101E-000, 5MP7151.101E-000 and 5MP7151.101E-001
Figure 36: Attachment shafts 5MP7150.101E-000,5MP7151.101E-000 and 5MP7151.101E-001
①
Multipoint connector: Connector for operating element signals
②
Multipoint connector: Main connector / Power supply and control lines
③
Ethernet connector / communication interface
3.3.2 Installing cables in the attachment shaft
After opening the attachment shaft, the connecting lines can be installed as shown in the following section.
Information about opening the attachment shaft
•
Place the Mobile Panel device on a clean flat surface with the display facing down in a way that
does not damage the Mobile Panel or its operating elements (e.g. ESD mat).
•
Use a size 10 Torx screwdriver to open and close the attachment shaft.
Information about changes in the attachment shaft
•
Disconnect the main connector (ST1) by pulling carefully on its wires with your fingers (do not
use sharp objects to help).
•
When disconnecting the RJ45 connector (ST2), make sure that the locking clip is pushed down.
ST2
ST1
ST1
1
2
Figure 37: Disconnecting ST1 and ST2
Warning!
•
When connecting the main connector and RJ45 connector, it is important to ensure that they
snap into place. Otherwise, the stop/enabling functionality or correct shielding cannot be en-
sured.
•
Before the Mobile Panel is recommissioned, the stop and enabling functionality must be
checked.