1.3 Installation with retaining clips
Retaining clips are used to mount PP500 devices with a diagonal of 5.7" or 7".
Figure 57: Retaining clips
Retaining clips are designed to clamp a maximum thickness of 6 mm and minimum thickness of 2 mm.
A large flat-head screwdriver is needed to tighten and loosen the screws. The maximum torque for the retaining
clips is 0.5 Nm.
Devices must be installed on flat, clean and burr-free surface; uneven areas can cause damage to the display
when the screws are tightened or intrusion of dust and water.
1.3.1 Procedure
1. Insert the device into the front side of the smooth, flat installation cutout. The required dimensions of the
installation cutout can be found in section 3 "Individual components".
2. Place the retaining clips on the B&R device. To do this, hook the clips into the openings on the sides of the
B&R device (indicated by the orange circles). The number of openings may vary depending on the size of
the device.
Figure 58: Inserting the retaining clips
3. Slide the retaining clips all the way to the back of the openings.
Figure 59: Sliding the retaining clips back