Maintenance / Service • Exchanging a PCI SATA RAID hard disk in a RAID 1 system
400
Automation PC 810 with GM45 CPU board user's manual V1.28
11 Exchanging a PCI SATA RAID hard disk in a RAID 1 system
In the example, the assumption is made that the secondary hard disk (HDD1) is defective in a RAID 1 configuration.
In such a case, the defective hard disk can be replaced by the replacement drive SATA hard disk.
Model number - PCI SATA RAID controller
Model number of required
replacement SATA HDD
Note
5ACPCI.RAIC-01
5ACPCI.RAIC-02
60 GB hard disk
5ACPCI.RAIC-03
5ACPCI.RAIC-04
160 GB hard disk
5ACPCI.RAIC-05
5MMHDD.0250-00
250 GB hard disk
5ACPCI.RAIC-06
5MMHDD.0500-00
500 GB hard disk
Table 297: Overview of required replacement SATA HDD for PCI SATA HDD RAID controller
A size 10 Torx screwdriver is needed for exchanging the hard disk.
11.1 Procedure
1. Disconnect the power supply.
2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body.
3. Remove the side cover.
4. Remove the SATA RAID insert.
5. Loosen the 4 appropriate mounting screws (M3x5).
Secondary Hard Disk
(HDD1)
Primary Hard Disk
(HDD0)
Figure 274: Screw layout on the back side of the SATA RAID controller 5ACPCI.RAIC-03
6. On the front side, slide the hard disk down and away (Figure 275: Hard disk exchange - left image).
7. Insert the new hard disk carefully into the connector (Figure 275: Hard disk exchange - right image), being
careful to only touch it on the front, and not on the top.