Technical data • Individual components
100
Panel PC 2100 swing arm user's manual V1.12
Model number
5ACCIF01.FPLK-000
Interfaces
POWERLINK
Quantity
1 (integrated 2-port hub)
Transmission
100BASE-TX
Type
Type 4, redundant
2)
Design
Shielded RJ45
Transfer rate
100 Mbit/s
Cable length
Max. 100 m between two stations (segment length)
Electrical characteristics
Power consumption
1.75 W
Operating conditions
EN 61131 pollution degree
Pollution degree 2
Environmental conditions
Temperature
Operation
-20 to 55°C
Storage
-20 to 60°C
Transport
-20 to 60°C
Relative humidity
Operation
5 to 90%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical characteristics
Weight
25 g
Table 97: 5ACCIF01.FPLK-000 - Technical data
1)
Yes, although applies only if all components installed within the complete system have this certification and the complete system itself carries the corresponding
mark.
2)
For more information, see Automation Help (Communication - POWERLINK - General information - Hardware - IF / LS).
3.4.3.3.1 POWERLINK 1 interface - Pinout
The POWERLINK 1 interface on the system unit is referred to as IF1.
POWERLINK 1 - IF1
1)
Cabling
S/STP (Cat 5e)
Cable length
Max. 100 m (min. Cat 5e)
Status LED
On
Off
Green
See Status/Error LED.
Link LED
On
Off
Yellow
Link (POWERLINK net-
work connection available)
Activity (blinking - da-
ta transfer in progress)
RJ45, female
1
Status LED
Link LED
Table 98: 5ACCIF01.FPLK-000 - POWERLINK 1 interface
1)
The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by
the particular operating system.
3.4.3.3.2 POWERLINK 2 interface - Pinout
The POWERLINK 2 interface on the system unit is referred to as IFx.
POWERLINK 2 - IFx
1)
Cabling
S/STP (Cat 5e)
Cable length
Max. 100 m (min. Cat 5e)
Status LED
On
Off
Green
See Status/Error LED.
Link LED
On
Off
Yellow
Link (POWERLINK net-
work connection available)
Activity (blinking - da-
ta transfer in progress)
RJ45, female
1
Status LED
Link LED
Table 99: 5ACCIF01.FPLK-000 - POWERLINK 2 interface
1)
The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by
the particular operating system.