X20 system modules • Counter modules • X20DC4395
864
X20 system User's Manual 3.10
4.11.17.12.4.3 Set mask of the digital channels
Name:
CfO_OutSetMask
The settings in this register only affect the values written to registers 4.11.17.12.4.5 "DigitalOutput02 to 08".
•
0 allows manual setting of digital outputs using registers DigitalOutput02 to 04
•
1 prevents manual setting of digital outputs using registers DigitalOutput02 to 04
When "1" is used, the "output event function" can be used to reset the outputs.
Data type
Value
USINT
See bit structure.
Bit structure:
Bit
Description
Value
Information
0
Reserved
-
0
Writing 1 to the DigitalOutput02 register sets the output
1
DigitalOutput02
1
Writing 1 from the DigitalOutput02 register does not set the out-
put
2
Reserved
-
0
Writing 1 to the DigitalOutput04 register sets the output
3
DigitalOutput04
1
Writing 1 from the DigitalOutput04 register does not set the out-
put
4
Reserved
-
0
Writing 1 to the DigitalOutput06 register sets the output
5
DigitalOutput06
1
Writing 1 from the DigitalOutput06 register does not set the out-
put
6
Reserved
-
0
Writing 1 to the DigitalOutput08 register sets the output
7
DigitalOutput08
1
Writing 1 from the DigitalOutput08 register does not set the out-
put