RS-232 Control Port
The RS-232 port refers to the main RJ-45 connection
located on the receiver's back panel. The RJ-45
contains connections for transmission and reception of
RS-232 data. See pin-out at right. The RJ-45 also
supports power supply and IR input for CK1.2 Keypad
interface.
Port -
When disabling the RS-232 port, RS-232 strings
will be neither transmitted nor received through the
main RJ-45 jack. By default the RS-232 port is enabled.
Baud rate -
The default baud rate is 9600. B & K does not recommend using any baud rate other than 9600.
When a Baud rate other than 9600 is used, Keypad status will not function.
Echo -
Enabled or Disabled.This setting is for those with external control systems communicating to B & K
products via RS-232. Echo will repeat RS-232 transmissions received through the main RJ-45 receive port.
Feedback (RS-232 Continuous Reply):
None (Default)
= Neither BKC-DIP Update or Reply is generated.
Update
= A change affecting a logical zone from the Front Panel or
B & K IR generates an update message representing the specific front panel
button or B & K IR command. The receiver must then be polled to determine
the current status.
Reply
= When set to “REPLY”, the receiver will automatically
generate BKC-DIP reply messages to allow unsolicited continuous feedback
to an external RS-232 controller. A change affecting Zone A or Zone B from
the Front Panel or B & K IR generates a reply message representing the new
status of the parameter that was changed.
Typical format example of a BKC-DIP Reply :
An example BKC-DIP Reply message the AVR507 Series2 or AVR505 Series2 will automatically generate
when a master volume change is executed in Logical Zone 1 is (0,R,P1=FF,1=60;). Reply message Logical
Zone 1 current Preset parameter Volume value is set to 60 hex or 0dB (assumes 0dB is the current setting).
“0” is the transmit ID
“R” is the BKC-DIP Reply message.
“P1=FF” is the BKC-DIP command for the current preset in logical Zone 1 (P1: main theater zone ID).
“1=60” is the current preset parameter (1: Volume), is set to the Hex value of 60 (volume at 0dB ).
For a complete list of B & K RS-232 parameter Protocol, see the
Series_IIIS2_10000.pdf
or greater located in
the documentation of BKcSuite or online at B & K ’s website.
All
(Both) = Outputs both a BKC-DIP Update and Reply messages.
Receive ID / Transmit ID -
This is the identifier in B & K RS-232 protocol that allows B & K to “listen” (receive
ID) or “talk” (transmit ID) to other B & K products. Change this identifier if you are using an external automa-
tion system to control more than one B & K products in series. The transmit and receive IDs are denoted by
the first number in an RS-232 message i.e. (
0
,S,I,1=45;).
Note -
If you change the Receive or Transmit ID, it does not affect setup with BKcSuite.
ADVANCED MENU SYSTEM SETUP
36
R
RS
S-
-2
23
32
2
P
PO
OR
RT
T
S
SE
ET
TU
UP
P
1
1
P
Po
or
rt
t
E
En
na
ab
bl
le
ed
d
2
2
B
Ba
au
ud
d
r
ra
at
te
e
9
96
60
00
0
3
3
E
Ec
ch
ho
o
D
Di
is
sa
ab
bl
le
ed
d
4
4
F
Fe
ee
ed
db
ba
ac
ck
k
N
No
on
ne
e
5
5
R
Re
ec
ce
ei
iv
ve
e
I
ID
D
0
0
6
6
T
Tr
ra
an
ns
sm
mi
it
t
I
ID
D
0
0
↑↑↓↓
n
ne
ex
xt
t
i
it
te
em
m
E
EN
NT
T
s
se
el
le
ec
ct
t
M
ME
EN
NU
U
a
ad
dv
va
an
nc
ce
ed
d
s
se
et
tu
up
p
IR
12v
12v
CTR
TX
12v
TX
RCV
12VDC Power Supply
IR
IR Input
CTR
12VDC Control Output
RS-232 Host Transmit
Signal/Common Ground
RCV
RS-232 Host Receive
Содержание AVR505 SERIES 2
Страница 60: ...ON SCREEN MENU FLOW CHART 58 AVR 505 or 507 Series 2 Menu System...
Страница 61: ...ON SCREEN MENU FLOW CHART 59...
Страница 62: ...NOTES 60...
Страница 63: ...NOTES 61...