Transparency
Sets the opaqueness of the Structure overlay. With minimum transparency settings, the chart
details are almost hidden by the StructureMap overlay.
Palette
Selects Structure palette.
Contrast
Determines the brightness ratio between light and dark areas of the screen.
Water column
Shows/hides the water column in Live mode.
If turned OFF schools of bait fish might not be seen on the SideScan image.
If turned ON the accuracy of the SideScan image on the map might be affected by the water
depth.
Frequency
Sets the transducer frequency used by the unit. 800 kHz offers the best resolution, while 455
kHz has greater depth and range coverage.
Noise rejection
Signal interference from bilge pumps, engine vibration and air bubbles can clutter the sonar
screen. The noise rejection option filters the signal interference and reduces on-screen
clutter.
Clear live history
Clears existing live history data from the screen and begins showing only the most current
data.
Record data
Records StructureScan data.
Source
Selects StructureMap source.