manualshive.com logo in svg
background image

User instructions

3 4

 

RM

High-performance ultrasonic and rinsing baths

Valid for: 

RM 16.2 UH, RM 16.2 U, RM 16.2 H, RM 16.2

RM 40.2 UH, RM 40.2 U, RM 40.2 H, RM 40.2

RM 75.2 UH, RM 75.2 U, RM 75.2 H, RM 75.2

23726a GB/2020-07

Содержание SONOREX TECHNIK RM 16.2 UH

Страница 1: ...tructions 3 4 RM High performance ultrasonic and rinsing baths Valid for RM 16 2 UH RM 16 2 U RM 16 2 H RM 16 2 RM 40 2 UH RM 40 2 U RM 40 2 H RM 40 2 RM 75 2 UH RM 75 2 U RM 75 2 H RM 75 2 23726a GB...

Страница 2: ...nt the original version will take prec edence BANDELIN accepts no responsibility or liability for damages caused by improper handling or usage contrary to the intended purpose The documentation was pr...

Страница 3: ...f unauthorised alterations modifications both the warranty claim and the CE conformity will no longer be valid If service is required please contact the specialist dealer in charge or the manufacturer...

Страница 4: ...general 8 1 4 1 Tank size RM 16 2 9 1 4 2 Tank size RM 40 2 10 1 4 3 Tank size RM 75 2 11 1 5 Warnings and safety precautions 12 2 Preparation 13 2 1 Scope of delivery 13 2 2 Set up assembly 13 2 3 St...

Страница 5: ...r 22 6 1 Maintenance 22 6 2 Functional checks 22 6 3 Error analysis 23 6 4 Repairs and service 23 7 Accessories 25 7 1 Required accessories 25 7 2 Optional accessories 26 7 3 Chemical preparations Rec...

Страница 6: ...ate on the rear side of the ultrasonic bath Product features Stainless steel oscillating tank 1 with transducers ultrasound frequency 40 kHz Easy to clean stainless steel housing 2 Filling level mark...

Страница 7: ...ction of stable emulsions or the rapid degasification of fluids with a high gas content 1 2 Purpose SONOREX TECHNIK ultrasonic baths are intended for the sonication of aqueous liquids They work on the...

Страница 8: ...er see type plate on rear of device Degree of protection IP 32 according to DIN EN 60529 Environmental conditions pursuant to EN 61 010 1 Overvoltage category II Degree of contamination 1 Permissible...

Страница 9: ...Filling volume l 14 Operating volume l 13 Inlet and outlet 3 way ball valve G Weir outlet G 1 outside Heating power W 800 800 Fuses heating T7A 6 3 32 T7A 6 3 32 Fuses generator F2A 5 20 F2A 5 20 Peak...

Страница 10: ...ng volume l 36 Operating volume l 31 Inlet and outlet 3 way ball valve G Weir outlet G 1 outside Heating power W 1300 1300 Fuses heating F10A 6 3 32 F10A 6 3 32 Fuses generator F2A F4A 5 20 F2A F4A 5...

Страница 11: ...volume l 72 Operating volume l 62 Inlet and outlet 3 way ball valve G Weir outlet G 1 outside Heating power W 1950 1950 Fuses heating F10A 6 3 32 F10A 6 3 32 Fuses generator F2A F6 3A 5 20 F2A F6 3A 5...

Страница 12: ...operating and external personnel from inadvertently coming into contact with the bath liquid or being injured by liquids that are still hot Operation and transport Observe ambient and set up condition...

Страница 13: ...d these must be immediately notified in writing to the transportation company and to the supplier Before startup the ultrasonic bath is to be left to stand at its operating location for 2 hours so tha...

Страница 14: ...stop or back it o by rotating it slightly to the left this will cause the PTFE tape to lose its sealing e ect 5 Close ball valve turn the lever 5 upwards 2 3 Start up Thoroughly rinse the ultrasonic o...

Страница 15: ...time switch Timed operation Turn knob to the right range of time 1 15 minutes Green control light is illuminated Once the time has elapsed the time switch automatically turns o By turning the knob bac...

Страница 16: ...ed again 4 Use Sonication or rinsing always take place directly in the tank For this purpose the objects are placed in a basket and hung inside the tank which is filled with bath fluid 4 1 Instruction...

Страница 17: ...ing objects Fully remove air bubbles from cavities e g blind holes Notes Temperature and heating Heated fluids intensify the ultrasound e ect Experience has shown that the best results are obtained wi...

Страница 18: ...fluid that has remained in the oscillating tank for a longer period of time must be degassed prior to use See also chapter 4 3 1 Remove basket and other accessories from the oscillating tank Place li...

Страница 19: ...With every object inserted the fill level is to be controlled Step 5 Ultrasound Operation Fundamentally the sonication time is to be as short as possible in order to protect the objects to be treated...

Страница 20: ...ocess and an improvement in the ultrasound e ect 4 3 2 Disposal of sonication fluids The working solution is disposed of pursuant to the specifications in the product leaflet and the label supplied by...

Страница 21: ...leaning product without any abrasive additives Do not use steel wool scrapers or graters for cleaning maintenance Metal particles that remain on the stainless steel surface as well as rust particles f...

Страница 22: ...n can be checked using a standard wattmeter It should be inserted between the ultrasonic bath s mains plug and the socket Fill the tank with fluid see chapter 4 2 For testing purposes only the ultraso...

Страница 23: ...d Heating system defective The ultrasonic bath can be readily operated without heating Slight erosion visible on the bottom of the bath Natural wear Ultrasonic bath OK Strong erosion marks appear at t...

Страница 24: ...if necessary see the upcoming chapter Decontamination certificate If the ultrasonic rinsing bath is sent back to the manufacturer for repairs with accessories if applicable the form Certificate of De...

Страница 25: ...Website 49 0 30 768 80 0 www bandelin com 7 1 Required accessories The baskets and basket holder for example are required accessories Do not stand or lay any objects directly on the tank bottom Access...

Страница 26: ...4 8507 WG 40 4 8509 WG 75 4 8518 Filtration with prefilter and main filter including connection set FA 16 8608 FA 40 8609 FA 75 8610 Oil separator incl connection set OX 16 8600 OX 40 8601 OX 75 8602...

Страница 27: ...onnected to the ultrasonic cleaning tank when cleaning very oily or greasy parts Impurities that rise to the surface of the tank are led via the weir into the oil separator where they are separated by...

Страница 28: ...e to the product information Do not ingest or inhale the preparations and do not allow them to come into contact with the eyes or skin Specimens in powder form may only be used in fully dissolved form...

Страница 29: ...tion mildly acidic pH 3 6 1 application 0 1 5 2 l 5 l 25 l 200 l 866 893 895 851 Special alkaline cleaner Resinous flux solder ing pastes ionic and non ionic residue drill ing grinding polishing and l...

Страница 30: ...oot fats oils waxes pigments coatings silicone oils flux oxide on non ferrous and precious metals Non ferrous and precious metals iron steel glass ceramics plastics rubber test sieves circuit boards f...

Страница 31: ...tronic waste If decontamination is incomplete cannot be correctly performed a material safety data sheet for the liquids used must be a xed to each device Metal accessories such as the lid or basket s...

Страница 32: ......

Страница 33: ...e SONOREX TECHNIK Modular Program can be assembled individually It is comprised of e cient ultrasonic baths and rinsing tanks in di erent sizes with and without heating as well as a large variety of a...

Страница 34: ...Note The user instructions in this and other languages as well as further information can be found on the enclosed CD...