Sectional Door Opener

installation instructions

Smart Pro, Smart  

& Secure

These instructions are intended for professional garage door 
opener installers. 
All references are taken from inside looking out.

DOC#   

161083_01

RELEASED:   

15/12/22

Smart Pro, Smart & Secure

(SDO-9V3, SDO-7V3 & SDO-6V3)

Содержание Smart Pro SDO-9V3

Страница 1: ...ion instructions Smart Pro Smart Secure These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161083_01 RELEASED 15 12 22...

Страница 2: ...ny fixed controls permanently fix the label concerning the manual release adjacent to its actuating member after installation ensure that the mechanism is properly adjusted and that the drive reverses...

Страница 3: ...ox 9kgs Practice correct lifiting techniques when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm gr...

Страница 4: ...battery is swallowed or enters the body it can cause severe internal burns and can lead to DEATH in as little as 2 hours Always completely secure the battery compartment If the battery compartment do...

Страница 5: ...rated angle which MUST be securely fastened to a structural support You will need to locate the structural beams in the ceiling which are generally 400mm apart ii does it have exposed beams The opener...

Страница 6: ...o Extension Kit 3156mm Rail 1 Extension Kit 3946mm Rail 2 Extension Kits 4736mm Rail refers to 3160 rail 170mm 1 8 2 5 Position Perforated Angle The Opener a MUST BE installed in a dry position protec...

Страница 7: ...al supports otherwise opener failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profression...

Страница 8: ...bt about the door s strength reinforcement may be added to the door s frame where necessary Door damage may occur if the bracket is installed on a panel with insufficient strength The opener s warrant...

Страница 9: ...he beam 100mm above the ground level as per AS NZS 60335 2 95 2020 This can be achieved by ensuring the bottom of the receiver and transmitter are 65mm above ground level They should also be placed as...

Страница 10: ...180mm 180mm Rated load 450N 400N 400N Maximum lifting under spring tension 200N 20kg 200N 20kg 200N 20kg Receiver type Multi frequency Multi frequency Multi frequency Receiver code storage capacity 6...

Страница 11: ...e speed not suitable release button THEN HOLD Each press changes speed as per table MAIN LIGHT BEEPER SPEED MODE x 3 3 x FAST Default x 2 2 x MEDIUM x 1 1 x SLOW RELEASE When at desired speed S T E P...

Страница 12: ...D lit Press repeatedly R E P R O F I L I N G T H E D O O R HOLD for 2 secs Door will open and close Re profiling is a simple way of re learning the travel characteristics of a previously setup Limit S...

Страница 13: ...e tension Should the door become hard to operate or completely inoperative contact a door professional d Guide Tracks Clean the internal sections of the guide tracks every 3 6 months with a cloth damp...

Страница 14: ...after hitting an obstruction or stalling ii Safety Beam triggered auto close the door will auto close after a programmed time In this mode the timer starts counting down only when the safety beam is t...

Страница 15: ...S O R I E S Alignment Mode is entered Ensure Alignment For PE Beams HOLD for 2 secs till 3 beeps are heard OFF Then replace controls cover Re registering is required every time an accessory is remove...

Страница 16: ...a pen HOLD for 2 sec the middle button through the coding hole S T E P T H R E E Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Take new remote RELEASE S T E P F I V E Press to test Opene...

Страница 17: ...emove controls cover till remote LED lit Press repeatedly I N S T A L L I N G W A L L R E M O T E C O N T R O L S T E P T W O HOLD Opener flashes beeps HOLD for 3 sec HOLD for 3 sec RELEASE Release bo...

Страница 18: ...connecting to wifi Remove controls cover Press repeatedly LED will turn PURPLE HOTSPOT ON S T E P T H R E E Open APP and click START W A R N I N G This device allows for operation of the door when not...

Страница 19: ...D I S E N G A G E T H E O P E N E R 2 0 M A N U A L D O O R O P E R AT I O N C A U T I O N W h e n t h e o p e n e r i s m a n u a l l y d i s e n g a g e d t h e d o o r i s n o l o n g e r l o c k e...

Страница 20: ...r stopped 6 MODE Yellow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 BATTERY STATUS LED Yellow Illuminates when battery is charged and flashes when bat...

Страница 21: ...ter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter throug...

Страница 22: ...E beam being blocked on closing hit an obstruction etc Also can occur if battery is activated x 4 or x 5 Position Fault x 6 Motor driving in wrong direction x 7 Memory fault x 8 Motor current sensor f...

Страница 23: ...ening of door mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure...

Страница 24: ...old waste facilitates the recovery of organic materials through alternative waste technologies such as composting Batteries and heavy metals are known contaminants in compost The community supports re...

Страница 25: ...Y LED off Battery not used not fitted solid Battery charged flash 2 secs in use holding STOP for 10s will shutdown flashing Battery charging when connected to power rapid flashing Battery failed fault...

Страница 26: ...E N T M O D E I N S T R U C T I O N S S T E P T W O S T E P F O U R If no beep is heard max or min setting is reached Press to move through options as per table below OR Observe the number of flashes...

Страница 27: ...to save Then refit controls cover Press to exit Remove controls cover till gear LED flashing Press repeatedly When activated PET mode drives the door to a preset position from the close position there...

Страница 28: ...CLOSE limit should be when rubber strip touches the ground to Close S T E P T H R E E W A R N I N G In setting the close limit position do not force the door into the floor with excessive force as thi...

Страница 29: ...ia Pty Ltd 29 your representative is Smart Pro Smart Secure installation instructions G Setting up Tilt Door Prior to limit set up the opener can be set to J Type Tilt Profile This process allows the...