6
Power Drive & Roll-A-Pro
®
installation instructions
WARNING!
A portable power generator
is not recommended due to spikes,
surges and fluctuations in the supply.
85
41
135
95
Minimum Side room
Recommended Side room
4.2 Unsuitable Door Types
The drive must not be used with a door incorporating a wicket
door, unless the drive cannot be operated with the wicket
door open. The fitting of an opener to doors with removable
mullions is not recommended.
4.3 Sideroom
The minimum sideroom required from the edge of the door
curtain is 41mm to the inside of the door bracket, and 85mm
to the wall. If a Battery Backup is to be fitted, at least 135mm
to the bracket is required.
Therefore the recommended sideroom from the edge of the
door curtain is 95mm to the inside of the door bracket, and
135mm to the wall as per diagram.
4. Setup Requirements
4.1 The Opener:
a. MUST BE installed in a dry position, protected from weather. (Moisture or corrosion not covered by Warranty)
b. Is factory set for RIGHT HAND SIDE installation (from inside garage), but capable of LEFT HAND SIDE installation.
c. REQUIRES properly earthed 3 pin single phase power within an arms length of door and at a suitable height
d. Requires a MINIMUM SIDEROOM of 41mm from the edge of the door to the inside of the door bracket and 85mm
to the wall.
e. CAN NOT be installed on a Door Axle Diameter that exceeds 35mm.
LEFT HAND SIDE
RIGHT HAND SIDE
40mm
40mm
85mm
85mm