background image

11

Power Drive & Roll-A-Pro

®

  installation instructions

10.2 Clearing the Door Limit Positions 

S T E P   O N E

S T E P   T W O

S T E P   T H R E E

Remove controls cover

C L E A R I N G   T H E   D O O R   L I M I T   P O S I T I O N S

HOLD

for 6 sec

Till LED 

flashes quickly

Release

NOTE: No action taken within 

30 secs, the opener returns to 

original settings.

Now set Close & Open limits

NOTE:

 If unhappy with the travel limit settting, restart this 

procedure by clearing the door limit positions as per below 

first.

10.4 Re-profiling the Door 

S T E P   O N E

S T E P   T W O

Remove 

controls cover

R E - P R O F I L I N G   T H E   D O O R

HOLD

for 6 secs

Door will open and close 

several times

Re-profiling is a simple way of re-learning the travel 

characteristics of a previously setup Limit Switch 

travel.  Re-profiling is used when travel characteristic 

change due to mechanical adjustments.

tip

To initiate a re-profile: LIMITS must already be set.

opener 

beeps once

RELEASE

S T E P   T H R E E

opener 

beeps once

Then refit 

controls cover

10.3 Controller memory reset

S T E P   O N E

S T E P   T W O

C O N T R O L L E R   M E M O R Y   R E S E T

HOLD

This will cause all control memory to be set to factory defaults

EXCLUDING: transmitters, history log and cycle counters.

If limits are already set, clear limits first by following 

Clearing the door limit positions and then follow 

below.

tip

Switch power OFF

Switch power 

ON

till all 

LED’s off

then 

Release

To clear the controller:

10.5 Setting the PET (PEdestrian) mode postion

When activated, PET mode drives the door to a 

preset position from the close position, therefore 

allowing a pet or parcel to go under the door.

tip

S E T T I N G   T H E   P E T   M O D E   P O S I T I O N

HOLD

Close to 

desired position

Remove controls cover

S T E P   T H R E E

S T E P   F O U R

Proceed to Storing 

the transmitter 

Code to code a 

remote button to 

PET Mode

Refit controls 

cover

HOLD

for 6 secs

+

till both LED’s 

are lit

Release

S T E P   O N E

S T E P   T W O

Содержание Controll-A-Door RDO-1V4

Страница 1: ...Door Opener installation instructions Power Drive Roll A Pro These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161061...

Страница 2: ...fications 19 21 Troubleshooting 20 22 After Installation Care 22 22 1 Service Checklist 22 22 2 Battery Replacement 23 22 3 Battery Disposal 23 22 4 Warranty 23 WARNING IMPORTANT SAFETY INSTRUCTIONS F...

Страница 3: ...n instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact wh...

Страница 4: ...or service BATTERY WARNING This product contains a lithium button coin cell battery in the transmitters If a new or used lithium button coin cell battery is swallowed or enters the body it can cause s...

Страница 5: ...t Transmitter Roll A ProTM 3 x TB 7 Transmitters 1 x Wall Visor Clip 4 1 x Collar Kit 5 1 x Weight Bar Fastner Bag 6 2 x Nilock Nut 7 2 x 2 x 3 16 x 1 2 flat washers 8 2 x Pan Head Screw M4 x 50 9 2 x...

Страница 6: ...s to be fitted at least 135mm to the bracket is required Therefore the recommended sideroom from the edge of the door curtain is 95mm to the inside of the door bracket and 135mm to the wall as per dia...

Страница 7: ...then the door may require servicing 5 2 8 5 Door Preparation 5 1 Prepare the Door a Clean the guides if there is any oil or wax present using a suitable white spirit The only lubricant suitable for us...

Страница 8: ...the end opposite to where the opener will be fitted check that the U bolt which holds the door axle to the bracket is tightened securely b Open the door completely and tie rope around the door roll D...

Страница 9: ...string down to disengage opener Slide opener over door axle c Secure with two 2 Flat washers 12 and two 2 Hex serration head screws 13 d Check the drive gear rotates freely by pulling the string hand...

Страница 10: ...S T E P T W O HOLD Press to close door S T E P T H R E E W A R N I N G In setting the close limit position do not force the door into the floor with excessive force as this can interfere with the eas...

Страница 11: ...initiate a re profile LIMITS must already be set opener beeps once RELEASE S T E P T H R E E opener beeps once Then refit controls cover 10 3 Controller memory reset S T E P O N E S T E P T W O C O N...

Страница 12: ...d not exceed 20 kg CAUTION Take care when completing a safety test Failure to follow this warning can result in serious personal injury and or property damage WARNING If the door is closing and is una...

Страница 13: ...80 ma V EB1 0V EB2 0V OSC AUX External device Alarm Door or Gate opener V EB1 0V EB2 0V OSC AUX 12 3 Remote Aerial Some sites cause poor radio reception Particularly problematic areas are those where...

Страница 14: ...from remote controllers that have been programmed into its memory Up to 64 remotes 8 for Roll A Pro can be programmed S T E P T H R E E Switch power on Press and release HOLD for 3 sec HOLD for 3 sec...

Страница 15: ...imes S T E P F I V E Turn on HOLD for 4 sec RELEASE Turn off Press then try another remote LED will be lit and light flash LED will go out Refit controls cover 14 5 Coding for AUX Output A U X O U T P...

Страница 16: ...er ALL stored codes deleted S T E P T W O HOLD for 6 sec RELEASE LED will flash rapidly 14 8 Installing the Wall Mounted Transmitter S T E P T H R E E I N S T A L L I N G W A L L R E M O T E C O N T R...

Страница 17: ...e t h e o p e n e r a f t e r t h e d o o r i s c l o s e d T O E N G A G E T H E O P E N E R WA R N I N G P l e a s e t e s t t h e m a n u a l r e l e a s e m e c h a n i s m t o e n s u r e t h a...

Страница 18: ...pted Rapid flashes Button Function 1 OPERATE Opens stops closes the door 2 CODE SET LED Red Flashes when a code is being stored or when the transmitter button is pressed 3 CLOSE LIMIT LED Red Illumina...

Страница 19: ...350N Short Term Peak Force 600N 60kg 500N 50kg Nominal force 200N 20kg 200N 20kg Receiver type Multi frequency Multi frequency Receiver code storage capacity 64 x Tri Tran 4 button Transmitters 8 x Tr...

Страница 20: ...r The transmitter range varies or is restricted Variations are normal depending on conditions e g temperature or external interference The battery life is exhausted Position of the transmitter in the...

Страница 21: ...ared Clear away any obstructions and test door closes correctly If door is damaged contact your door professional Remove all power sources including the battery backup Wait till all lights are out 10...

Страница 22: ...ening of door mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure...

Страница 23: ...Battery Disposal 22 2 Battery Replacement Some batteries are less toxic but hazardous for other reasons Lithium batteries can explode or catch fire in landfill while button cells are dangerous if swa...

Отзывы: