Cycle Programming Sequence
12
Chem 5
3
INC
Aux 1
3
INC
Aux Fill
3
INC
Aux 2
3
INC
Spin Test
3
INC
Agitation
3
INC
RPM
3
INC
Chem 6
3
INC
Chem 7
3
INC
Chem 8
3
INC
ON to turn on chemical signal 5, and
flush cup 5 in the supply dispenser, if
equipped. -- means the supply is off.
Auxiliary 1 output
ON turns on Auxiliary Fill.
-- means the valve is off.
Auxiliary 2 output
ON turns on drive balance relay - only
used in extract cycles. -- means the relay
is off.
ON enables the machine to rotate, in
concert with RPM, below. -- means
no cylinder rotation. More information
on page 8.
Set the RPM - see chart on page 29 for
details on recommended speeds for a
particular machine.
ON to turn on chemical signal 6.
-- means the supply is off.
ON to turn on chemical signal 7.
-- means the supply is off.
ON to turn on chemical signal 8.
-- means the supply is off.
continued
To turn on a function, press Enter, to turn off a function press Reset. Press Enter to edit a numerical
value (RPM, Time, etc.). Note: Setting a function to zero DOES NOT disable that function.